Alcatel-Lucent 1643 AMS Installation Manual page 210

Access multiplexer / access multiplexer small (formerly metropolis am / metropolis ams) release 1.0 through 7.2
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Stand-alone test procedures
Procedure
Proceed as follows to perform the X.21 option card test:
...................................................................................................................................................................................................
Assign the installed option card.
1
...................................................................................................................................................................................................
Change the default Alarm Reporting/Severity of the X21cNES (X21 Not Expected
2
Input Signal) alarm from reported "No" to "
...................................................................................................................................................................................................
Provision the following cross-connections for the applicable configurations:
3
Result:
Port under test
TP2.1
TP2.2
TP2.3
TP2.4
...................................................................................................................................................................................................
Set the PDH analyzer to 2 Mbit/s, 2
4
...................................................................................................................................................................................................
Connect the X.21 loop to TP2.1.
5
...................................................................................................................................................................................................
Monitor the analyzer for correct transmission. If a DDF is applied for the X.21 ports
6
then place the loop on the ports of the DDF.
...................................................................................................................................................................................................................................
7-20
Required cross-connections
S12, L12
TP2.1–CC1,2.111
CC1,1.111–TP1.1
TP2.2–CC1,2.112
CC1,1.112–TP1.2
TP2.3–CC1,2.113
CC1,1.113–TP1.3
TP2.4–CC1,2.114
CC1,1.114–TP1.4
15-1
PRBS pattern. Connect the analyzer to TP1.1.
Alcatel-Lucent - Proprietary
See notice on first page
".
Yes
S42, L42
TP2.1–CC1,2.111
CC1.2–LP2.1,1
CC1,1.111–TP1.1
CC1,1–LP1.1,1
TP2.2–CC1,2.112
CC1.2–LP2.1,1
CC1,1.112–TP1.2
CC1,1–LP1.1,1
TP2.3–CC1,2.113
CC1.2–LP2.1,1
CC1,1.113–TP1.3
CC1,1–LP1.1,1
TP2.4–CC1,2.114
CC1.2–LP2.1,1
CC1,1.114–TP1.4
CC1,1–LP1.1,1
X.21 option card test
365-312-802R7.2
Issue 4, June 2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1643 am

Table of Contents