YASKAWA SI-P3 Technical Manual page 24

Ac drive-option card profibus-dp
Hide thumbs Also See for SI-P3:
Table of Contents

Advertisement

8 Parameter Process Data Object Formats
ID
8
Change parameter value in array (double word)
9
Request number of array elements
Response ID
ID
0
No action
1
Transfer parameter value (word)
2
Transfer parameter value (double word)
4
Transfer parameter value (array word)
5
Transfer parameter value (array double word)
6
Transfer number of array element
7
Task cannot be executed (with error number)
SI-P3 Device Data
Parameter
GSD_Revision
Vendor_Name
Model_Name
Ident_Number
FMS_supp
Protocol_Ident
Station_Type
Slave_Family
Revision
Hardware_Release
Software_Release
Implementation_type
Redundancy
Repeater_Ctrl_Sig
24V_Pins
Set_Slave_Add_supp = 1
Auto_Baud_supp
9.6_supp
19.2_supp
45.45_supp
93.75_supp
187.5_supp
500_supp
1.5M_supp
3M_supp
6M_supp
12M_supp
MaxTsdr_9.6
MaxTsdr_19.2
MaxTsdr_45.45
MaxTsdr_93.75
MaxTsdr_187.5
MaxTsdr_500
MaxTsdr_1.5M
MaxTsdr_3M
MaxTsdr_6M
MaxTsdr_12M
Min_Slave_Interval
Freeze_Mode_supp
Sync_Mode_supp
Fail_Safe
DPV1_Slave
DPV1_Data_Types
C1_Read_Write_supp
C2_Read_Write_supp
C2_Max_Data_Len
C2_Response_Timeout
C2_Read_Write_required
C2_Max_Count_Channels
24
Description
Description
Setting Value
3
"YASKAWA ELECTRIC"
"PROFIBUS-DP INTERFACE CARD SI-P3"
0x0ACF
0
0
0
3
"V1.0"
"V1.0"
"V1.0"
"DPC31"
0
2
0
1
1
1
1
1
1
1
1
1
1
1
1
60
60
60
60
60
100
150
250
450
800
5
1
1
1
1
1
0
1
240
100
0
1
YASKAWA ELECTRIC SIEP C730600 42A YASKAWA AC Drive-Option Card PROFIBUS-DP Technical Manual
Note
GSD file revision 3.0.
PROFIBUS-FMS not supported
PROFIBUS-DP supported
DP-Slave.
Device revision 1.0
Hardware revision 1.0
Software revision 1.0
DP protocol
Redundancy NOT supported
Supported, TTL level
No external 24 Volt input
Station address is set remotely
Automatic baud rate select
9600 Baud
19.2 kBaud
45.45 kBaud
93.75 kBaud
187.5 kBaud
500 kBaud
1.5 MBaud
3 MBaud
6 MBaud
12 MBaud
60 Tbit = 6.25 msec
60 Tbit = 3.125 msec
60 Tbit = 1.32 msec
60 Tbit = 640 usec
60 Tbit = 320 usec
100 Tbit = 200 usec
150 Tbit = 100 usec
250 Tbit = 83 usec
450 Tbit = 75 usec
800 Tbit = 67 usec
Minimum slave interval=0.5 ms
Freeze mode not supported
Sync mode not supported
Fail safe supported

Advertisement

Table of Contents
loading