YASKAWA SI-P3 Technical Manual page 12

Ac drive-option card profibus-dp
Hide thumbs Also See for SI-P3:
Table of Contents

Advertisement

5 Installation Procedure
Installing the Option Card
Insert the option card in the CN5-A connectors located on the drive's control board.
See the drive manual for directions on removing the front cover.
1.
Shut off power to the drive, wait the appropriate amount of time for voltage to dissipate, then remove the operator and front cover.
2.
Insert the CN5 connector on the option card into the matching CN5 connector on the drive, then fasten it into place using one of the screws
included with the option card.
Connect one of the lead lines using one of the screws to the ground terminal.
Three separate lead lines have been included with the option card to connect to three separate ports. Use the lead line with the length
appropriate for the distance of the port.
Note: There are only two screw holes on the drive for ground terminals. If three option cards are connected, two of the lead lines will need to share the same ground terminal.
Figure 4
3.
Wire the option card to the communication cable connector on the option card.
For exposed cables in drives 2A004 to 0069, 4A0002 to 0044, use a pair of wire cutters to create an opening on the left side of the front
cover that allows wiring to pass through. Sharp edges along the opening that was created should be smoothed down with a file or sand
paper so prevent any damage to the wires.
Drives 2A0081 to 0021, 4A0058 to 0165 have enough space to keep all wiring inside the unit.
Figure 5
A
4.
Place the front cover back onto the drive as it was before.
Note: 1. Take care when wiring the option card so that the front cover easily fits back onto the drive.
2. Install Cable Cover option to maintain the drive Enclosure Type.
5.
Attach the LED label packaged with the option card as shown in
12
A
B
C
D
G
A – Connector CN5-C
B – Connector CN5-B
C – Connector CN5-A
D – Drive grounding terminal (FE)
E – Insert connector CN5 here
F – Option card
Figure 5 Installing the Option Card
A – Opening for cable lines
(2A0004 to 0069, 4A0002 to 0044)
YASKAWA ELECTRIC SIEP C730600 42A YASKAWA AC Drive-Option Card PROFIBUS-DP Technical Manual
E
F
H
G – Lead line
H – Use wire cutters to create an
opening for cable lines
I – Operator
J – LED label
K – Front cover
B – Space for wiring
(2A0081 to 0211, 4A0058 to 0165)
Figure 6 Wiring space
Figure
5.
I
RUN
COMM
ERR
BF
J
K
B

Advertisement

Table of Contents
loading

Table of Contents