YASKAWA SI-P3 Technical Manual page 23

Ac drive-option card profibus-dp
Hide thumbs Also See for SI-P3:
Table of Contents

Advertisement

IND
Bit
0
1
2
3
Sub-Index for parameter number
(F6-33 = 0)
4
5
6
7
8
9
10
11
Sub-Index for parameter number
(F6-33 = 1)
12
13
14
15
PWE
Bit
0 to 31
Setting Data
STW/ZSW
Bit
0
OFF1: reserved
1
OFF2: reserved
2
OFF3: reserved
Enable to RUN
3
0: Baseblock + Stop
1: Not Baseblock
0: STOP
4
1: RUN
5
Ramp function generation enable: reserved
6
Enable ramp function generator set-point: reserved
7
1: Fault Reset
0: Stop
8
1: JOG RUN forward (Fmax/10 speed)
0: Stop
9
1: JOG RUN reverse (Fmax/10 speed)
0: Local control
10
1: Control from PROFIBUS
11
12
13
Reserved
14
15
HSW/HIW
Bit
0 to 15
Setting Frequency (±10000/100%)
Task ID
ID
0
No action
1
Request parameter value
2
Change parameter value (word)
3
Change parameter value (double word)
6
Request parameter value from array
7
Change parameter value in array (word)
YASKAWA ELECTRIC SIEP C730600 42A YASKAWA AC Drive-Option Card PROFIBUS-DP Technical Manual
PPO Write
Sub-Index for parameter number
(F6-33 = 0)
Sub-Index for parameter number
(F6-33 = 1)
PPO Write
Error code when Response ID is 7
0: Incorrect PNU number
1: Write mode error
2: Lower or upper limit violated
3: Disabled IND is set
17: Write mode error during Uv condition or Write mode error during
parameter processing
PPO Write
PPO Write
Description
8 Parameter Process Data Object Formats
PPO Read
PPO Read
PPO Read
Ready to switch on: always 1
Ready: always 1
0: Not ready
1: Drive ready
0: No fault condition
1: Fault condition
Always 1
Always 1
Switch-on inhibit: always 0
0: No alarm condition
1: Alarm condition
0: No speed agree
1: Speed agree condition
0: Local control
1: Control from PROFIBUS
Always 0
PPO Read
Output Frequency or Motor speed (with PG) (±10000/100%)
23