Step 12
(Only for T852/T862) Locate the Top Truss Cables (for T852: PN 1300011017-00/for T862: PN
1300011707-00). Secure the Truss Cables on Truss Support with (2) 3/8" Cable Clamp on the Truss
Support (Do not overtighten the clamp, as the cable has to move freely through the clamp) (see
Figure 12.1). Secure the one of end of cable with the Eyebolt at Intake and Mid Tubes connecton
using (2) (for T852: 5/16" Cable Clamps/for T862: 3/8" Cable Clamps) (see Figure 12.2) (Aways have
saddles of the Cable Clamps on the "live" end of the Cable as shown in figure 12.3). Secure the other
end of the Truss Cable with the Quick Link at Discharge End using (2) (for T852: 5/16" Cable
Clamps/for T862: 3/8" Cable Clamps) (see Figure 9.3). To tighten the cables, lifting the Discharge end
of the tubes is required. Place lifting strap 2 feet from the end of the Auger and lift the tubes
approximately 3 feet. This will cause the tubes to curve upwards. Place a punch or pry bar into the
eye of the Eyebolt to hold it straight. Tighten the Nut on the Eyebolt approximately 3" or until the
Cable feels stiff. Do this for all the cables.
Figure 12.1: Truss Support Connection
Figure 12.3: Cable Calmp on Cable
ASSEMBLY
TUBE ASSEMBLY
"Live"
Cable to Truss
Cable
Clamp Saddle
B9
1300060439-81-00
Figure 12.2: Eyebolt Connection
Figure 12.4: Quick Link Connection