Danfoss VLT FC 101 Quick Manual page 47

Hvac basic drive
Hide thumbs Also See for VLT FC 101:
Table of Contents

Advertisement

Specifications
Frequency converter
Typical shaft output [kW]
Typical shaft output [hp]
Protection rating IP20
Maximum cable size in terminals
(mains, motor) [mm
2
(AWG)]
Output current - 40 °C (104 °F) ambient temperature
Continuous (3x380–440 V)[A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum input current
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum mains fuses
Estimated power loss [W],
best case/typical
1)
Weight enclosure protection rating
IP20 [kg (lb)]
Efficiency [%], best case/typical
2)
Output current - 50 °C (122 °F) ambient temperature
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Table 6.3 3x380–480 V AC, 18.5–90 kW (25–125 hp), Enclosure Sizes H5–H8
1) Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/
vltenergyefficiency.
2) Efficiency measured at nominal current. For energy efficiency class, see chapter 6.3.12 Ambient Conditions. For part load losses, see
www.danfoss.com/vltenergyefficiency.
MG18A802
Quick Guide
P18K
P22K
P30K
18.5
22.0
30.0
25.0
30.0
40.0
H5
H5
H6
16 (6)
16 (6)
35 (2)
37.0
42.5
61.0
40.7
46.8
67.1
34.0
40.0
52.0
37.4
44.0
57.2
35.2
41.5
57.0
38.7
45.7
62.7
29.3
34.6
49.2
32.2
38.1
54.1
412/456
475/523
733
9.5 (20.9)
9.5 (20.9)
24.5 (54)
98.1/97.9
98.1/97.9
97.8
34.1
38.0
48.8
37.5
41.8
53.7
31.3
35.0
41.6
34.4
38.5
45.8
Danfoss A/S © 05/2016 All rights reserved.
P37K
P45K
P55K
37.0
45.0
55.0
50.0
60.0
70.0
H6
H6
H7
35 (2)
35 (2)
50 (1)
73.0
90.0
106.0
80.3
99.0
116.0
65.0
80.0
105.0
71.5
88.0
115.0
70.0
84.0
103.0
77.0
92.4
113.0
60.6
72.5
88.6
66.7
79.8
97.5
922
1067
1133
24.5 (54)
24.5 (54)
36.0 (79.4) 36.0 (79.4)
97.7
98
98.2
58.4
72.0
74.2
64.2
79.2
81.6
52.0
64.0
73.5
57.2
70.4
80.9
P75K
P90K
75.0
90.0
100.0
125.0
H7
H8
120
95 (0)
(250MCM)
147.0
177.0
161.0
194.0
130.0
160.0
143.0
176.0
140.0
166.0
154.0
182.0
6
120.9
142.7
132.9
157.0
1733
2141
51.0
(112.4)
97.8
97.9
102.9
123.9
113.2
136.3
91.0
112.0
100.1
123.2
45
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt hvac basic drive fc 101

Table of Contents