Leica Builder T User Manual page 218

Version 4.0
Table of Contents

Advertisement

Technical Data
Atmospheric condi-
tions
Accuracy
The range on the round prism is only achievable with the upgraded distance meas-
urement. Otherwise the specifications of the CPR111 are valid (max. 1000 m). Please
refer to "5.4 Distance Measurement".
1:
Strong haze, visibility 5km; or strong sunlight, severe heat shimmer
2:
Light haze, visibility about 20km; or moderate sunlight, slight heat shimmer
3:
Overcast, no haze, visibility about 40km; no heat shimmer
Standard measuring
Fine
Fast
Tracking
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
Builder
Standard deviation,
ISO 17123-4
2 mm + 2 ppm
5 mm + 2 ppm
5 mm + 2ppm
Measure time, typical [s]
< 1
< 0.5
< 0.3
218

Advertisement

Table of Contents
loading

This manual is also suitable for:

Builder rmBuilder rm powerBuilder m powerBuilder r

Table of Contents