Check & Adjust
Step
Description
1.
Set up the provided CPR105 flatprism between 5 m and 20 m with the
reflective tape side facing the instrument.
2.
Align the instrument crosshairs to the centre of the flatprism.
3.
Switch on the red laser beam by activating the laser pointer function in
Configuration Mode.
4.
Without using the telescope inspect the position of the red laser dot on
the flatprism.
Look at the flatprism from just above the telescope or from just
to the side of it.
5.
If the dot is within the inner printed circle the laser beam is within toler-
ance. If it is outside it is recommended to have the laser beam realigned
by a Leica Geosystems authorized service workshop.
Builder
179