Leica Builder T User Manual page 217

Version 4.0
Table of Contents

Advertisement

Reflector range
(fine/fast mode)
Technical Data
Standard measuring
CPR105 Flat prism
(Cat-eye)
CPR105 Flat prism
(Reflective tape)
Tracking
Object in shade, sky overcast.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 1 mm.
Range of measurement :
Type
CPR111 BUILDER
prism, true-zero offset
Round prism
Standard deviation,
ISO 17123-4
5 mm + 2 ppm
3 mm + 2ppm
5 mm + 2 ppm
1.5 m to 3500 m
Range 1
Range 2
[m]
[ft]
[m]
450
1500
800
1800
6000
3000
Builder
Measure time, typical [s]
< 2
< 2
1.0
Range 3
[ft]
[m]
[ft]
2600
1000
3500
10000
3500
12000