Application Programs, for Builder R, RM,
M power and RM power
Description of fields
Field
Description
<Pt:>
The identifier for the points to be staked.
Available for Builder RM, M power and RM power.
<Line:>
Available if a Setup method with Control Line was used.
Longitudinal offset of the start point of the control line in the direc-
tion of the second point of the control line.
Line is positive in the direction from line start point to second line
point.
<Offs:>
Available if a Setup method with Control Line was used.
Cross offset to the control line.
Offset is positive at the right hand side of the control line.
<E:>
Available if a Setup method with Coordinates was used.
Easting of point to be staked.
<N:>
Available if a Setup method with Coordinates was used.
Northing of point to be staked.
<H:>
Height of point to be staked.