Automatic spray gun M -10
5.4

Mounting the automatic spray guns

Changing the installation position of the spray gun
The automatic spray gun can be mounted on both sides on the retaining bolts in order to
change the installation position.
Fig. 3: Mounting the automatic spray guns
1.
Slide the automatic spray gun ( Fig. 3/1) with the respectively designed drill hole over the
retaining bolt ( Fig. 3/3).
2.
Fix retaining bolt with installation screws ( Fig. 3/2).
3.
Ensure proper earth connection of the automatic spray gun.
5.5

Connecting the automatic spray gun

See also (
Ä Chapter 5.3 'Connection scheme' on page 17).
WARNING!
Danger of injury due to improper connection!
When the fluid supply is pressurised, e.g. from pressure containers or with pumps, the range
of the fluid jet can increase by a multiple in case of atomisation air failure. This presents a
hazard to people and property.
Make sure that the fluid supply and the control air are interrupted if the atomisation air
pressure drops off quickly.
It is recommended to regulate the atomisation air pressure via a filter pressure reducer.