5.3

Mounting the automatic spray guns

Fig. 3: Mounting the automatic spray gun
1.
Slide the spray gun with the fastening hole ( Fig. 3/1) over an on-site retaining bolt (Æ = 12
mm).
2.
Fasten the automatic spray gun with the screws ( Fig. 3/2) (tightening torque:
'Technical data' on page 40).
3.
Ensure proper earth connection of the automatic spray gun.
5.4

Connection scheme

Air and fluid supply
Fig. 4: Air and fluid supply
St
Control air
Z
Atomisation air
DV
Pressure regulator valve
O/S
Opener/closer with bleed
(E)
H
Tap
GB–16
Operating instructions
M
Material
F
Filter
DE
Pressure generator
––––
Fluid supply
- - - -
Air supply