Installing The Automatic Spray Gun; Connecting The Automatic Spray Gun - Krautzberger MC1 Operating Instructions Manual

Automatic spray gun
Table of Contents

Advertisement

6.3

Installing the automatic spray gun

Changing the installation position of the automatic spray gun
The automatic spray gun can be mounted on both sides on the retaining bolts in order to
change the installation position.
Fig. 2: Installing the automatic spray gun
1.
Slide the automatic spray gun ( Fig. 2/1) with the intended drill hole over the retaining bolt (
Fig. 2/2).
2.
Fix the retaining bolt in place on the underside of the automatic spray gun using the instal-
lation screws ( Fig. 2/3).
3.
Ensure proper grounding of the automatic spray gun.
6.4

Connecting the automatic spray gun

WARNING!
Danger of injury due to improper connection!
When the material supply is pressurised, e.g. from pressure containers or with pumps, the
range of the material jet can increase by a multiple in case of atomizer air failure. This
presents a hazard to people and property.
Make sure that the material supply is interrupted if the atomizer air pressure drops off
quickly.
It is recommended to regulate the atomizer air pressure via a filter pressure reducer.
The connections for the material input and for the atomiser air are marked with letter codes.
GB–18
Operating instructions
T-Dok-689-GB-Rev.1
mail@krautzberger.com, www.krautzberger.com