Emerson SI-EtherCAT User Manual page 95

Table of Contents

Advertisement

10.3.2
Error code
Table 10-6 Error code
0x603F
Error code
Access: RO
Default:
0
A non-zero value in this object indicates that an error has occurred. The value
Description:
will be one of the codes described in Table 10-7 below.
Table 10-7 Error codes
Error code
0x0000
Error reset / No error
0xFFO1
Generic error
0x2300
Current, device output side
0x3130
Phase failure
Short circuit/ground leakage
0x2230
(device internal)
0x3210
DC link over-voltage
0x3230
Load error
0x4310
Excess temperature drive
"Supply low voltage" and "U2 =
0x5112
supply +24 V"
0x5200
Control device hardware
0x5400
Power section
0x5510
RAM
Data Storage (Non-volatile data
0x5530
memory)
0x5430
Input stages
0x5440
Contacts
0x6010
Software reset (watchdog)
0x6320
Parameter Error
SI-EtherCAT User Guide
Issue Number: 2
Range: 0 to 0xFFFF
Meaning
Size: 2 bytes
Corresponding drive trip Code (if available)
0 – None
(Any trip code not elsewhere in table)
3 – OI ac
32 – Phase Loss
98 - Out Phase Loss
5 – PSU
9 – PSU 24V
92 - Snubber OI
2 – Over Volts
38 - Low Load
21 – OHt Inverter, 22 – OHt Power
23 – OHt Control, 27 – OHt dc bus
101 - OHt Brake
91 - User 24V
200 - Slot 1 Hardware Fault
203 - Slot 1 Not Fitted, 204 - Slot 1 Different
205 - Slot 2 Hardware Fault
208 - Slot 2 Not Fitted, 209 - Slot 2 Different
210 - Slot 3 Hardware Fault
213 - Slot 3 Not Fitted, 214 - Slot 3 Different
250 - Slot 4 Hardware Fault
253 - Slot 4 Not Fitted, 254 - Slot 4 Different
221 - Stored HF
111 - Config P
220 - Power Data
223 - Rating Mismatch
227 - Sub Array RAM Allocation
31 – EEPROM Fail
36 – User Save
37 – Power Down Save
94 - Rectifier set up
226 - Soft Start
30 – Watchdog
199 - Destination
216 - Slot App Menu Crash
217 - App menu changed
Unit: N/A