Technical specifications
7.4 Technical data
Immunity to RF interference
Magnetic field
Voltage dips
Voltage interruptions
Ambient conditions
Climatic ambient conditions
Temperature
Operation
Storage/transportation
Relative humidity
Operation
Storage/transportation
Atmospheric pressure
Operation
Storage/transportation
Mechanical ambient conditions
Vibration
Storage/transportation
Resistance to shock
Storage/transportation
Special features
Quality assurance
Altitude of operation (m)
Pollution Degree
No burner operation
1
At +5 °C to +35 °C without restrictions, even burner operation
76
Radiation Immunity (to IEC 61000-4-3)
80-1000 MHz: 10 V/m, 80% AM (1 kHz)
1.4 - 2 GHz: 3 V/m, 80% AM (1 kHz)
2 - 2.7 GHz: 1 V/m, 80% AM (1 kHz)
Conducted Immunity (to IEC 61000-4-6)
150 kHz - 80 MHz: 10 V, 80% AM (1 kHz)
50 Hz / 60 Hz, 30 A/m (to IEC 61000-4-8)
> 95% reduction, 0.5 cycles (to IEC 61000-4-11)
> 30% reduction, 25/30 cycles at 50/60 Hz (to IEC 61000-4-11)
> 95% reduction, 250/300 cycles at 50/60 Hz (to IEC 61000-4-
11)
Tested in accordance with IEC 60068-2-2, IEC 60068-2-1,
IEC 60068-2-14
5 °C to +40 °C
1
Gradient:≤ 10 °C/h, no condensation
–20 °C to +60 °C
Gradient:≤ 20 °C/h, no condensation
Tested in accordance with IEC 60068-2-78, IEC 60068-2-30
5% to 80% at 25 °C, no condensation
Gradient:≤ 10 °C/h, no condensation
5% to 95% at 25 °C, no condensation
Gradient:≤ 20 °C/h, no condensation
1013 to 795 hPa, (0 to +2000m)
1013 to 660 hPa, ( 0 to +3500m)
Tested in accordance with IEC 60068-2-6, 10 cycles
5 to 8.4 Hz, amplitude 3.5 mm; 8.4 to 500 Hz: 9.8 m/s
Tested in accordance with IEC 60068-2-27
Half-sine: 250 m/s
, 6 ms, 1000 shocks per axis
2
In accordance with ISO 9001
Up to 2000 m
2