Summary of Contents for Siemens SIMATIC IPC477E PRO
Page 1
Preface Overview Safety guidelines SIMATIC Mounting and connecting the HMI device Industrial PC SIMATIC IPC477E PRO Commissioning the device Operating the device and device functions Operating Instructions Expanding the device and assigning the device parameters Maintaining and repairing the device...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Connecting the device to networks ..................51 4.4.5 Securing the cables ........................ 52 Commissioning the device ........................53 Notes on commissioning and operation .................. 53 Initial commissioning ....................... 55 Windows Action Center......................57 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 4
8.5.4 Update installation ....................... 101 8.5.4.1 Updating the operating system .................... 101 8.5.4.2 Installing or updating application programs and drivers ............101 8.5.5 Backing up data ........................101 Recycling and disposal ......................101 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 5
Resetting the Intel® AMT to the default settings and disabling AMT ........148 9.7.5 Determining the network address ..................148 9.7.6 Forcing user consent ......................149 Functional scope in Windows ....................150 9.8.1 Windows Embedded Standard 7 ..................150 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 6
Markings and symbols ......................... 157 Overview ..........................157 Safety ........................... 157 Operator controls ......................... 157 Certificates, approvals and markings ................... 158 Interfaces ..........................159 List of abbreviations ..........................161 Glossary .............................. 167 Index ..............................175 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions apply to "SIMATIC IPC477E PRO" industrial PCs with article numbers6AV7251-...-..Scope of this documentation The documentation for the IPC includes the following: ●...
Page 8
A note is important information about the product, handling the product or a reference to specific sections of the documentation that require special consideration. History The following editions of these operating instructions have already been published: Edition Comments 08/2017 First edition SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Overview Product description Features SIMATIC IPC477E PRO provides high-level industrial functionality. ● Compact design ● Maintenance-free operation ● IP65 degree of protection ● Rugged ● Ex approval ● Used for shipping and offshore applications ● Expansion with system components The range has been expanded by the PRO device with all-round IP65 degree of protection;...
Page 10
The delivery note contains information on the precise scope of functions and product package for your device. The SIMATIC IPC477E PRO is available in the following device variants, which differ in regard to the display size, operating method and optional expansions: PRO device with capacitive multi-touch screen ●...
Overview 2.2 Installation Installation Front view and side view ① Display with multi-touch screen ② Enclosure ③ Backplane cover ④ Terminal compartment cover Bottom view ① Mechanical interface for mounting/base adapter SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 12
① Backplane cover ② Terminal compartment cover ③ Mechanical interface for mounting/base adapter Rear view - device version "prepared for support arm and extension components" ① Terminal compartment cover SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Article number for the base adapter as accessory: 6AV7674-1KA00-0AA0. See also Prepared for support arm or stand without extension elements (flange on top) (Page 35) Industry Mall (https://mall.industry.siemens.com) Expansion components and accessories (http://www.automation.siemens.com/mcms/pc- based-automation/en/industrial-pc/expansion_components_accessories) SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
① Flange mount ② Ring groove for fastening on PRO device with setscrews ③ Mechanical interface to support arm Article number of the flange mount: 6AV7674-1KF00-0AA0 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 17
You can find information on mounting the PRO device at Prepared for support arm and extension elements (flange mount) (Page 38). You can find Information on available accessories on the Internet at: ● Industry Mall (https://mall.industry.siemens.com) ● System components for devices with all-round IP65 protection https://mall.industry.siemens.com/mall/de/de/Catalog/Products/10268745?tree=CatalogTree...
Adapter set for support arm and stand mounting of PRO device The PRO device can be mounted on systems from third-party vendors (see section "Mounting the device (Page 33)"). For this you will need the Siemens base adapter (see Base adapter (Page 15)) and a proprietary adapter set.
In addition, different operator controls such as emergency stop, selector switch, illuminated pushbutton, keyswitch, indicator light or RFID reader are available. Note Only operator controls with Siemens approval may be installed in the Extension Unit. You can find information on "System components for PRO device Extension Units" on the Internet (https://support.industry.siemens.com/cs/de/de/view/109742323/en).
Page 20
Overview 2.5 System components Additional information Information on system components for devices with all-round IP65 protection is available on the Internet (https://mall.industry.siemens.com/mall/de/de/Catalog/Products/10268745?tree=CatalogTree SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
• Only install system expansion devices designed for this device. Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. • Read the information on electromagnetic compatibility (Page 108). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 22
When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline (Page 108). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 23
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
• Always use suitable cleaning agents. Read the information about Chemical resistance of the HMI devices and industrial PCs (http://support.automation.siemens.com/WW/view/en/39718396) on the Internet. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 25
A small number of defective pixels in the display is therefore unavoidable. This does not present a functional problem as long as the defective pixels are not bunched in one location. Additional information is available in the section "General technical specifications (Page 120)". SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 26
Safety guidelines 3.2 Notes on usage SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
• Keep the original packaging. • Pack the device in the original packaging for transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 28
7. Please keep the enclosed documentation in a safe place. It belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Certificate of Authenticity partment) Windows operating system. Ethernet address 1 BIOS setup, "Advanced" menu Ethernet address 2 Ethernet address 3 Example of a SIMATIC IPC477E PRO rating plate SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 30
● COA label of a device with the Windows Embedded Standard 7 operating system ● COA label of a device with Windows 7 operating system ● COA label of a device with Windows 10 operating system SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Deviation from the vertical position ① Inclined ≤ 45° ② Vertical 0° Device version "prepared for support arm without extension components (flange at top)" Mounting position ① Inclined ≤ 45° ② Vertical 0° SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 32
Mounting and connecting the HMI device 4.2 Permitted mounting positions Device version "prepared for support arm and extension components (round tube)" Mounting position ① Inclined ≤ 45° ② Vertical 0° SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Only use a support arm system or pedestal system that has IP65 degree of protection and Enclosure Type 4X / 12 (indoor use only). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 34
Liability disclaimer The device is mounted to a pedestal or a support arm via the mechanical interface with screws. Siemens AG assumes no liability for the consequences of incorrect installation. Warranty at risk If you do not install the HMI device in accordance with the specifications in these operating instructions, the warranty for the device is voided.
Requirements ● All packaging components and protective films have been removed. ● Siemens base adapter with screws (supplied with the device version "prepared for support arm without extension components (flange at top)" and "prepared for pedestal/extension components (flange at bottom)").
Page 36
If you tighten the screws with a torque that is too low, the device is not sealed. 1. If an adapter plate for the Siemens base adapter is included in your support arm system, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
Page 37
7. Connect all cables according to the description in the section Connecting the device (Page 42). ⑤ 8. Fasten the cover plate to the device with the 2 screws, torque 1.5 Nm. Check that the seal is sitting correctly. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
– Support arm with mechanical interface, appropriate for the flange of the flange mount, and Siemens flange mount (not included in product package) – Support arm with mechanical VESA interface, the corresponding Siemens adapter set and the Siemens flange mount (not included in product package) See System components (Page 15)) ●...
Page 39
4.3 Mounting the device Procedure The following description shows an example of how to attach the PRO device to a support ⑦ arm system using the optionally available Siemens flange mount . Mounting to a 48.3 mm ⑧ round tube that fits the opening of the PRO device is performed in a similar fashion.
Page 40
⑨ 4. If an adapter plate for the Siemens flange mount is included with your support arm, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
Page 41
9. Fasten the cover plate from the PRO device product package with 4 M4x12 screws, torque 1.5 Nm. Alternatively, you can extend the PRO device by adding an Extension Unit at the bottom. Read the associated documentation. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
• Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 43
Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
● The device is disconnected from the power supply. ● Torx TX20 screwdriver Opening the terminal compartment cover Opening the terminal compartment cover for pedestal and support arm device versions without extension components. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 45
The assignment of the interfaces is shown on the inside of the terminal compartment cover. ① 3. Run the connecting cables through the support arm or pedestal into the PRO device and connect them to the interfaces on the inside. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 46
If you tighten up the M4x16 screws with a torque of > 1.5 Nm, you may damage the threading in the enclosure. 3. Tighten the M4x16 screws of the terminal compartment cover using a maximum torque of 1.5 Nm. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Tighten the M4 screw with a torque of max. 1.5 Nm. 3. Connect the protective conductor to the protective conductor connection of the control cabinet from which the PRO device is supplied. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
● The corresponding 24 V DC power supply is switched off. ● A two-core cable with a cable cross-section of ≥ 0.5 mm for the 24 V DC connection. ● A slotted screwdriver with approx. 3 mm blade. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 49
The connecting terminal must snap into the connection socket. Secure the power supply cable to the strain relief with a cable tie. Similar to figure SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The product supplier in each case provides support for the USB devices. Moreover, the terms of liability of the individual vendors or suppliers apply here. Note Strain relief Use the metal eyelets on the rear side to mount the cable strain reliefs for cable ties. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Control level. Information on this can be found on the SIMATIC NET Manual Collection CD. The software package and the documentation are not included in the product package. Additional information You can find additional information on the Internet at: Technical Support (https://support.industry.siemens.com) SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
3. Secure each cable connected to the device to the strain relief using a cable tie or fixing screws for the D-sub connectors. The required cable ties are not included. ① Fastening with cable ties 4. Cut off the protruding ends of the cable ties. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Configuring memory cards in the device Memory cards used in a device need to be configured on that device. Memory cards configured on other devices will not boot as the drive parameters will be different. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 54
● The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse Note Switching on the PRO device An external on/off switch is recommended to avoid having to continually open the terminal compartment cover. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The product key is located on the "Certificate of Authentication", in the "Product Key" line. Result The interface of the operating system is displayed every time you turn on the device and after the startup routine. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 56
If the device is not going to be used for a long period of time after shutdown, set the on/off switch to the position. NOTICE Disconnecting the device from the power supply The on/off switch does not separate the device from the mains. To de-energize the device, remove the power supply terminal. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Windows settings. You can then either acknowledge this warning or prevent the program from changing the Windows settings. This option is enabled for Windows 7 and Windows Embedded Standard 7 with the factory settings. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 58
Commissioning the device 5.3 Windows Action Center SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Only touch the touch screen with your fingers or a suitable touch stylus. ● On-screen keyboard ● External keyboard, connected via USB ● External mouse, connected via USB ● Touch pen SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Incorrect operation of devices with a touch screen can occur. This can result in personal injury or property damage. Take the following precautions: • Configure the plant so that safety-related functions are not operated with the touch screen. • Switch off the device for cleaning and maintenance. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 61
– Surface contact with a diameter of > 3 cm, for example, resting the palm of the hand on the touch screen – As soon as the touch screen is no longer touched, input is possible again. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
– IPCScreenSaver All other functions are described in the manual "SIMATIC IPC Wizard 2.1 and Panel Configuration Center": ● On the supplied USB stick ● In the IPC Wizard installation directory on the PC SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
SIMATIC IPC DiagMonitor is available on CD (not included in the scope of delivery). The CD contains both the monitoring software and the software for the stations to be monitored. The interface specifications and a library for creating your own applications are also provided. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
A watchdog alarm is retained after a restart and is reset and logged by the DiagBase or DiagMonitor software. The watchdog configuration is retained in the process. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
When the first warning level is reached, the battery for buffering CMOS data still has a remaining service life of at least one month. 6.4.1.5 Mass storage monitoring The state of the SSD and CFast cards is monitored via SMART bit and reported by DiagBase or DiagMonitor. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
● "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager Configure the SIMATIC IPC UWF Manager with: ● "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings ● Click the "SIMATIC IPC EWF Manager" icon in the system tray.
Page 67
The EWF commands affecting the write protection do not become active until after the next booting process. Note The EWF command cannot be used with the options (i.e. ewfmgr c: -commitanddisable –Live not like this: ewfmgr c: -commitanddisable –live SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 68
Start > Control Panel > Date and Time, remove the check mark from the "Automatically adjust clock for daylight saving changes" check box. 2. Save the change you have made with and then reboot the system. ewfmgr c: -commit SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
EWF and FBWF are pre-installed in the SIMATIC IPC images. Ensure that only one write filter is enabled on a partition, otherwise you risk data loss. Make sure that you only activate one write filter for each partition. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
A memory window with a maximum size of 512 KB can be displayed by means of PCI address register. The base address is initialized by the BIOS. A corresponding function is implemented there for using the NVRAM under WinAC RTX and for using the CPU150xS SW controller. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system. For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation: SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158)
Page 72
Configuration of the AMT PC You configure AMT by means of the BIOS setup and MEBx (Management Engine BIOS Extension). MEBx is a BIOS extension for configuration of AMT (see BIOS description in chapter "Technical specifications"). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 74
Operating the device and device functions 6.4 Extended device functions SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Expanding the device and assigning the device parameters Opening and closing the backplane cover Requirements ● The device is disconnected from the power supply. ● Torx TX20 screwdriver Opening the backplane cover SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 76
3. Remove the green connection terminal. The connection terminal is plugged in and can be pulled out from the front. ① 4. Loosen the eight M4x16 screws of the backplane cover (the screws are captive in the covers). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 77
③ 2. Pull out the cable connector (see section "Replace SSD (Page 89)"). ① 3. Unplug the power supply connector on the motherboard. 6. Now you can install and remove the hardware. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 78
5. Tighten the M4x16 screws of the backplane cover in crosswise order using a maximum torque of 1.5 Nm. Check all screws again to ensure that the maximum torque of 1.5 Nm has not been exceeded. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The motherboard is equipped with one slot for an SO-DIMM DDR4 memory module. You can use it to expand the memory capacity of the device to a maximum of 16 GB. Note Use only the memory modules recommended by Siemens AG. You can find additional information in the section "Accessories (Page 14)". Requirements ●...
Page 80
1. Insert the memory module into the marked slot at an incline with the contact side toward the motherboard. 2. Carefully press the memory module into the contact strip until the latches engage. 3. Close the device. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
• Do not insert CompactFlash cards (CF cards) into the slot for the CFast card. • Always replace the SIMATIC IPC CFast card with a SIMATIC IPC CFast card of the same production version or higher. For the SIMATIC IPC477E PRO, only SIMATIC CFast cards with production version 02 or higher may be used.
Same as standard, but additionally optimized for deterministic operation with optimized constant CPU frequency. Temperature Setting for lowest power consumption. optimized The CPU clock is limited at a higher load. The maximum power consumption of the CPU is 12 W. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
SMART status. As soon the SMART status of the SSD switches to "Not OK", a message is sent in DiagBase or DiagMonitor, or when you start up the PC. You should then back up your data and replace the drive. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
These safety steps must always be taken in the above order before any work on electrical systems. Once work on an electrical system is finished, cancel the safety steps starting with the last and finishing with the first. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 85
• You can take used batteries and rechargeable batteries to public collection points and wherever batteries and rechargeable batteries of the type in question are sold. • Mark used battery containers as "Used batteries". SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 86
UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Procedure 1. Switch off the device. 2. Dampen the cleaning cloth. 3. Spray the cleaning agent on the cloth and not directly on the device. 4. Clean the device with the cleaning cloth. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
1. Remove the labeled connector. 2. The battery is fastened with a Velcro fastener. Grip the labeled battery and carefully pull it out. For installation, proceed in the reverse order and reconnect the device. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
3. Remove the indicated screws and firmly ④ hold down the cover of the power supply. 4. Remove the drive cage with the SSD and power supply and place it with the back facing up. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 90
• M3 x 5 countersunk screws for mounting the SSD drive in the drive cage Proceed in reverse order for the installation. 1. In step 1 above, ensure that the connectors are not installed with reverse polarity. 2. Close the device. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The supplied USB flash drive contains the documentation, hardware drivers and updates. In Windows, these contents are available via a menu. Restore function If you have ordered IPC477E PRO with operating system, the supplied USB flash drive contains the Restore function. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
4. To boot from the USB flash drive, select the Boot Manager. 5. Select the USB flash drive in the Boot Manager and confirm the entry. 6. Select the Restore function and confirm the entry. 7. Follow the on-screen instructions. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Recovery function and confirm the entry. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 94
For this purpose, you can either select one of the preinstalled languages or install a new language package. The following command sequences are described in English. Depending on the default setting, they can be displayed in another language. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 95
"Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. You can make the required changes in the "Administrative" tab. You copy the settings by clicking the respective button. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 96
3. Click the "Install/uninstall languages" button and make the required changes. The following languages can be installed at a later time: Language Windows German English French Italian Spanish Chinese (Hong Kong) Chinese (simplified) Chinese (Taiwan) Japanese Russian SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Note the license terms of Windows Embedded Standard 7 Note the license terms for Windows Embedded Standard 7 and especially the extended software terms of the Siemens AG. You can find the license terms in the delivered document "MICROSOFT SOFTWARE LICENSE TERMS for Windows Embedded Standard 7"...
Remainder NTFS not compressed To restore the partitions to their original delivery state, we recommend you use the software SIMATIC IPC Image & Partition Creator. Additional information is available in the accompanying documentation. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
A partition can only be reduced if sufficient space is available. 1. Click with the right mouse button on the partition to be reduced and click on "Reduce size". 2. Follow the instructions. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
6. Open the folder with the driver information: Click on the link next to "Driver path". 7. Start the setup program in this folder. Note For a new installation of Windows operating systems, the chipset driver must be installed before all other drivers, if required. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
(images). The SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
Page 102
Maintaining and repairing the device 8.6 Recycling and disposal SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Panel PC certificates (http://support.automation.siemens.com/WW/view/en/10805572/134200). ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
Page 104
WARNING Risk of explosion when connecting or disconnecting the device EXPLOSION HAZARD WARNING - EXPLOSION HAZARD - Do not connect or disconnect while circuit is live unless area is known to be non-hazardous. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 105
For additional ATEX/IECEx-relevant information see document A5E37656836-AA and Internet (https://support.industry.siemens.com/cs/ww/en/view/109486065). Additionally to the installation instructions in the user manual of IPC477E the following specifications must be observed for installation in hazardous locations. See also Securing the cables (Page 52). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 106
CANADA Canadian Notice This Class A digital apparatus complies with Canadian ICES-003 (A). Avis Canadien Cet appareil numérique de la classe A est conforme à la norme NMB- 003 (A) du Canada. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 107
This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 109
There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 110
This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Technical specifications 9.3 Dimension drawings Dimension drawings 9.3.1 Dimension drawing of 15" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 112
Technical specifications 9.3 Dimension drawings Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 113
Technical specifications 9.3 Dimension drawings Prepared for support arm and extension components ① With flange mount SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
② Without flange mount All dimensions in mm 9.3.2 Dimension drawing of 19" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 115
Technical specifications 9.3 Dimension drawings Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 116
Technical specifications 9.3 Dimension drawings Prepared for support arm and extension components ① Without flange mount ② With flange mount All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Technical specifications 9.3 Dimension drawings 9.3.3 Dimension drawing of 22" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 118
Technical specifications 9.3 Dimension drawings Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 119
Technical specifications 9.3 Dimension drawings Prepared for support arm and extension components ① Without flange mount ② With flange mount SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
In accordance with ISO 9001 The device may only be connected to a 24 V DC power supply that meets the requirements of a safe extra-low voltage (SELV) according to IEC/EN/DIN EN/UL 60950-1. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 121
80% AM according to IEC 61000-4-3 3 V/m, 2 to 2.7 GHz 10 V, 10 kHz to 80 MHz according to IEC 61000-4-6 Immunity to magnetic fields 100 A/m, 50/60 Hz according to IEC 61000-4-8 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 122
1 × ≥ 80 GB; 2.5" SATA SSD or > 240 GB CFast card 2 GB optional or 4 GB optional or 8 GB optional or 16 GB optional or 30 GB optional SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 123
MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example time- controlled via screen saver or centrally via PROFIenergy. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 124
For unique labeling, the Ethernet ports are numbered on the enclosure. The numbering by the operating system can differ. Teaming can be set and initiated in the configuration interface. In teaming operation, jumbo frames, e.g. for the camera application, are not supported. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
5 to 8.4 Hz: 3.5 mm 8.4 to 200 Hz: 9.8 m/s Shock resistance, tested in accordance with IEC 60068-2-27, IEC 60068-2-29 Operation 50 m/s , 30 ms Storage/transport 250 m/s , 6 ms SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
+5 V +3.3 V +12 V USB device High current PRO device: 10 W for all USB devices DisplayPort 500 mA The total power for USB expansion may not exceed 15 W SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
The peak value of the starting current depends on the input voltage and the impedance of the 24 V DC power supply. Peak currents greater than 6.5 A are possible. This will not have a negative impact on device functionality. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
ISA exclusive IRQ3 Com Port 2 (COM2) ISA exclusive IRQ4 Com Port 1 (COM1) ISA exclusive IRQ5 Free ISA exclusive (CAN) IRQ6 Free IRQ7 Free IRQ8 System CMOS / real-time clock ISA exclusive SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Watchdog trigger register (read only, address 062h) Watchdog trigger register The watchdog is triggered by a read action (address 066h) by this register. The result of the read access can be disregarded (i.e., dummy read). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
960 ms / 64 s Trigger red Watchdog LED Red LED (WD) off Red LED (WD) on Watchdog error / Display and reset WD inactive WD triggered Reset LED after watchdog alarm (Bit 7 = write 1) SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189178 (http://support.automation.siemens.com/WW/view/en/92189178). SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Exit selection menu, continue start sequence Boot Manager Specify the boot media from which to start, for example: Hard disk drive • CD-ROM drive • USB device • Device Management Start device manager for UEFI boot media SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 138
Support (AMT) Available as of Windows 8, if supported by device Only if hardware supports AMT and the AMT option "Intel AMT Configuration Screens" is set to "Enabled" in the BIOS Setup. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Determine boot options, e.g., boot order Exit Save and exit (see Exit menu) The menus always have the same structure. The figure below shows an example for the "Main" menu. Device-specific information is shown blurred. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 140
Short help texts on the currently selected setup parame- ters are displayed in the center right-hand area. ⑤ Key assignment The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Requirement: The parameters are saved prior to this with "Save Custom Defaults". Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
BIOS update Check regularly if updates are available for download to your device. Additional information can be found on the Internet at the following address: After Sales Informations System of SIMATIC PC (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
Page 143
There may be several reboots after a BIOS update. These reboots are initiated by the Management Engine (ME). The reboots are required by the ME to adapt itself to the changes of the BIOS update. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
CMOS battery is empty or not connected. Real-time clock has lost power The CMOS clock was operated without battery or with a battery that was too weak, during bat- tery change, for example. Check the CMOS clock. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
SIMATIC IPC with Intel® AMT from it. The following figure shows remote maintenance of SIMATIC IPCs with Intel® AMT, e.g. for troubleshooting a corrupt operating system or incorrect BIOS settings: SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
6. Exit the BIOS Setup with <F10> key (Save and Exit). Settings in the MEBx 1. Use the arrow keys to select "MEBx" and confirm with the <Enter> key. 2. Select "MEBx Login". SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 147
5. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network with "Activate Network Access". 6. Confirm the dialogs that appear with "Y". Drivers are automatically installed once with the Windows system start in the subsequent restart. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
1. You can obtain the address of the AMT server in the command line in Windows using "ipconfig" and in UNIX using "ifconfig". If the AMT server and operating system do not use the same network address, ask your network administrator for the address you have been assigned. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Select "Opt-in Configurable from Remote IT". SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Available Available Printing Utilities and Management Available Available Registry Filter Available Available Remote Assistance Available Available Remote Client Available Available Remote Desktop Available Available SIMATIC IPC DiagBase Available Available Speech Available Not available SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 151
Windows Security Center Available Available Windows Update Available Available Wireless Networking Available Available Note the licensing agreements for Windows Embedded Standard 7. Additional information on language selection is available in the section "Windows (Page 93)". SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 152
Technical specifications 9.8 Functional scope in Windows SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
The operating system does not sup- Turn on USB Legacy Support for mouse and key- • port the USB ports. board. For other devices, you need the USB device driv- • ers for the required operating system. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Signal frequencies or signal • party expansion card was the cause of the fault. Replace levels are not adhered to this expansion card with a SIEMENS card or contact the Different pin assignment • card supplier. If the PC still crashes, contact your technical support team.
Page 156
Technical support A.3 Notes on the use of third-party modules SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 160
Markings and symbols B.5 Interfaces SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Complementary Metal Oxide Semiconduc- Complementary metal oxide semiconductors tors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer Central Processing Unit SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 162
Enhanced Write Filter Frequently Asked Questions FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table FBWF File Based Write Filter Floppy disk Disk drive, 3.5" Front Side Bus Ground Chassis ground SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 163
MS-DOS Microsoft Disc Operating System MTBF Mean Time Between Failures Multilanguage User Interface Multilanguage operating system with Windows with language toggling; 5 languages: German, English, French, Spanish and Italian Not Applicable SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 164
Reconciliation Sublayer 485 Bi-directional bus system designed for up to 32 nodes Real Time Clock Real-time clock Reliable Transfer Service Request to send Receive Data Data transfer signal SATA Serial Advanced Technology Attachment SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 165
Virtualization Technology Intel technology with which a virtually closed environment can be made available. VT-D Virtualization Technology for Directed I/O Enables the direct assignment of a device (e.g. network adapter) to a virtual device. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 166
Program monitoring with error detection and alarming. WLAN Wireless LAN Wireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
EC Directives, for example, with the EMC Directive. CFast card CFast is a digital storage medium in card form without moving parts. A CFast card uses the SATA protocol and its connectors are not compatible with a classic CompactFlash card. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 168
SETUP program. . Drivers Program parts of the operating system. They adapt user program data to the specific formats required by I/O devices such as hard disk, printers, and monitors. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 169
EFI is located logically beneath the operating system and represents the successor to PC BIOS, focusing on 64-bit systems. File Based Write Filter Configurable write filter to protect individual files from write access. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 170
Intel VT The Intel Virtualization Technology (IVT) is the implementation of a secure closed environment for applications. Special (visualization) software an a VT-capable processor is required for its use. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 171
Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
Page 172
Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. Restart Warm restart of a computer without switching the power off (Ctrl + Alt + Del) SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 173
This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 174
Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 176
Rear view, 12 IPC477E PRO 19" Touch Main dimensions, 114, 115, 116 IPC477E PRO 22" Touch Package contents, 27 Main dimensions, 117, 118, 119 Checking, 27 IT communication, 51 Packaging, 27 Checking, 27 Removing, 27 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 177
Windows Embedded Standard 7 Integration, 51 Setting up partitions, 98 Windows XP Professional Partitioning, 98, 99 Data backup, 101 Standard mounting position, 31 Startup, 144 Static electricity Protective measures, 110 System partition, 92 System resources, 131 SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Page 178
Index SIMATIC IPC477E PRO Operating Instructions, 08/2017, A5E39912462-AA...
Need help?
Do you have a question about the SIMATIC IPC477E PRO and is the answer not in the manual?
Questions and answers