Configuring Wired Bridging On Ethernet 0 For Mesh Point - Siemens SCALANCE W1750D UI Configuration Manual

Table of Contents

Advertisement

Mesh AP Configuration

28.3 Configuring Wired Bridging on Ethernet 0 for Mesh Point

28.3
Configuring Wired Bridging on Ethernet 0 for Mesh Point
SCALANCE W supports wired bridging on the Enet0 port of an AP. If AP is configured to
function as a mesh point, you can configure wired bridging.
Note
Enabling wired bridging on this port of an AP makes the port available as a downlink wired
bridge and allows client access through the port.
Note
When using 3G uplink, the wired port will be used as downlink.
You can configure support for wired bridging on the Enet0 port of an AP by using the
SCALANCE W UI or the CLI.
In the SCALANCE W UI
To configure Ethernet bridging:
1.
2.
3.
4.
5.
6.
In the CLI
To configure Ethernet bridging:
(scalance)# enet0-bridging
Note
Make the necessary changes to the wired-profile when eth0 is used as the downlink port. For
more information, see Configuring a Wired Profile on page 105
454
On the Access Points tab, click the AP to modify.
Click the edit link.
Click the Uplink tab.
Select Enable from the Eth0 Bridging drop-down list.
Click OK.
Reboot the AP.
Configuration Manual, 02/2018, C79000-G8976-C451-02