Configuring A Time Range Profile - Siemens SCALANCE W1750D UI Configuration Manual

Table of Contents

Advertisement

Configuring Time-Based Services

17.2 Configuring a Time Range Profile

17.2
Configuring a Time Range Profile
You can create time range profiles using the SCALANCE W UI or the CLI
In the SCALANCE W UI
To create a time range profile:
1. Navigate to System > Show advanced options > Time Based Services.
2. Click New under Time Range Profiles. The New Profile window for creating time range
profiles is displayed.
3. Configure the parameters listed in the following table:
4. Click OK
In the CLI
To create an absolute time range profile:
(scalance)(config)# time-range <name> absolute start <startday> <starttime> end
<endday>
<endtime>
(scalance)(config)# end (scalance)# commit apply
To configure a periodic time range profile:
(scalance)(config)# time-range <name> periodic {<startday>|daily|weekday|weekend}
<starttime> to <endtime> (scalance)(config)# end (scalance)# commit apply
296
Parameter
Name
Type
Period Type
Start Day and End Day
Start Time
End Time
Description
Specify a name for the time range profile.
Select the type of time range profile.
Periodic—When configured, the state of the AP changes based on
the time range configured in the profile.
Absolute—When configured, the state of the AP changes during a
specific date / day and time.
For periodic time range profiles, specify a periodic interval
(day/weekday/weekend/daily) at which the time range profile must
be applied.
For absolute time range profiles, specify the start day and the end
day to configure a specific time period during which the time range
profile is applied.
NOTE: The year selected for Start Day and End Day cannot exceed
the year 2037.
Select the start time for the time range profile in the hh:mm format.
Select the end time for the time range profile in hh:mm format.
Configuration Manual, 02/2018, C79000-G8976-C451-02
SCALANCE W1750D UI

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents