Default Settings (On Shipment from the Factory)

Initializing Settings

IM 767361-01E
Item
Functions Common to the MT210, MT210F, and MT220
Pressure zero calibration value
Units of pressure
Number of display digits
Relative display
Data hold
Pressure averaging
Back lighting
Key lock mode
Beep ON/OFF
Header for output data
Status byte interrupt setting
MT120 Only
Measurement mode
(normal, medium-speed, high-speed)
Dynamic mode (/DA option)
MT220 only
0% pressure value
100% pressure value
DMM function ON/OFF
Measuring object for DMM
DMM averaging
24 V output
Store mode
Storing rate (auto store mode)
Number of data stored (auto store mode)
Store memory no.
Recall memory no.
With GP-IB
GP-IB mode
Address
Delimiter
GP-IB ON/OFF
(when using DC or battery power)
With RS-232
RS-232 mode
Handshake mode
Format
Baud rate
Delimiter
/DA board
D/A output range (2V/5V)
Comparator output ON/OFF
Comparator lower limit
Comparator upper limit
D/A board ON/OFF
(when using DC or battery power)
*1 Yes: Backed up No: Not backed up
*2 Not initialized in the case of absolute pressure models (767357, 767367 and 767387).
*3 4-1/2 digits in the case of the 700 kPa models (767355, 767365, 767373, and 767385).
*4 Not initialized by the "RC" command since this setting is related to the communications interface
specifications.
*5 Off on the 767370. The initial pressure sample rate is 4 s.
*6 This value is not initialized since it is a critical value for the measured data memory function.
*7 This value is not initialized since it is a critical value for power supply control when operating on
battery or DC power.
Settings can be reset to their defaults (i.e. reset to the factory settings) in the
following two ways.
• By holding down the ENTER/LOCAL when the power switch is turned ON
until the model name and version number are displayed.
• By sending the RC communications command from the controller.
Before Starting Measurement
Default (Factory Setting)
0
*2
kPa
5-1/2
*3
OFF
OFF
ON
*5
OFF
OFF
ON
*4
Included
*4
31
Normal
OFF
0
Measuring range
ON
DC voltage (5 V range)
ON
OFF
Manual store mode
Each time one data item is updated
20
1
*6
1
*6
Addressable mode
*4
1
*4
0 (CR + LF + EOI)
*4
OFF
*7
*4
Normal mode
*4
0
*4
0
*4
9600
*4
0 (CR + LF)
2V
OFF
0
Measuring range
*7
OFF
Backup
*1
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
27