2.3.59 MASS STORAGE TABLE SIZE OPTION (RATl)
Definition:
The option RATL must equal the number of MST entries.
Option:
RATL
EQU
n
Dependency:
Number of MST entries.
Release value:
RA TL equals 5 on the MSOS COSY tape and the MSOS binary source
tape.
Decks and COSY numbers:
DELETE/
261
CIa
DECK/
p1,p2
2.3.59A REAL TIME OPTION (REALTIME)
Definition:
The REALTIME option enables the user to use real-time interrupts and
run real-time programs.
Option:
REALTIME
REALTIME
EQU
EQU
o
1
Real-time programs not enabled
Real-time programs are enabled
Dependency:
If real-time routines are to be utilized, REALTIME must remain set to
1.
Options P 1 or P2 must also be set.
Release value:
REALTIME equals 1 on the MSOS COSY and the MSOS binary source
tape.
Deck and COSY number:
DELETE/
18
CIC
DECK/
pl,p2
60410800 D
II-2-44.1
I