Low Battery Protection
System stays ON
Low Battery is
Detected
When the system is ON, and
(1) The battery voltage (DC input) is lower than LOW_THRESHOLD (at T
(2) and this situation lasts for LOW_DELAY,
, then the system will send Power Button signal to OS (at T
process.
At this time (T7), the LOW_HARD_DELAY is starting to countdown.
Once LOW_HARD__DELAY is over, the system power is removed abruptly.
LOW_DELAY is ranged from 1 to 3600 seconds.
LOW_HARD_ DELAY is fixed with a value of 60 seconds.
Note:
Q1: How is the low-battery event raised or canceled?
A1: The minimum value on LOW_DELAY parameter is 1 second. If the voltage remains
lower than the LOW_THRESHOLD in the duration of LOW_DELAY, the low-battery
event will be raised and immediately send a power button press signal to OS.
During the duration of LOW_DELAY, if the battery voltage is back to be higher than
LOW_THRESHOLD, the LOW_DELAY will be reset to predetermined value and stop
count down.
Therefore, the LOW_DELAY parameter acts as a filter to prevent incorrect
low-battery-event from happening.
4.3.2
Power Management demo program
TREK V3 VPM Sample Code
TREK V3 VPM Sample Code is demonstration of vehicle power management (VPM).
System Menu
 TREK V3 VPM Sample Code as below figure
42
www.advantech.com
LOW _DELAY
T
6
LOW_HARD_DELAY
T
7
Send Power
Button Signal
) to start the shutdown
7
T
8
System OFF
)