Installation as function module F24
2.4.4

Setting the operating mode

You set the operating mode of the bus node with switch element 1.1 of DIL switch 1.
Operating mode
Remote I/O operating mode
All functions of the CPX terminal are con­
trolled directly by the higher-order PLC/IPC.
The bus node undertakes the required con­
nection to CC-Link.
Not possible
The remote controller operating mode is
available only in the configuration as func­
tion module F23. The remote I/O operating
mode must be set in the configuration as
function module F24.
Tab. 2.1 Operating mode
Note
The setting of the operating mode with the DIL switch has priority over all other set­
tings.
Setting of the DIL switch 1.1 to ON causes a change to the configuration as function
module F23, independent of the setting of DIL switch 3.8 (è 2.4.6).