Setting The Baud Rate - Festo CPX-FB23 Description

Terminal cpx, bus node
Hide thumbs Also See for CPX-FB23:
Table of Contents

Advertisement

2
Installation as function module F24
2.4.5

Setting the baud rate

You can set the baud rate with the DIL switch elements 1.2 of the DIL switch 1 and the DIL switch ele­
ment 2.1 and 2.2 of the DIL switch 2.
Baud rate
156 kBd
625 kBd
2.5 MBd
5 MBd
10 MBd
Switch position combinations that are not presented are impermissible.
Tab. 2.2 Baud rate
The maximum range per segment is dependent on the baud rate (è Section 2.5.2).
16
Setting DIL switches 1.2 and 2
Festo – P.BE-CPX-FB23-24-EN – 1411b – English