Default Parameterisation; A.2 Default Parameterisation - Festo CPX-FB23 Description

Terminal cpx, bus node
Hide thumbs Also See for CPX-FB23:
Table of Contents

Advertisement

A
Technical appendix
Fieldbus
Status information
– Protocol
– Version
– CC-Link chip
– Vendor code
– Machine type
Transmission rates
(The maximum permitted fieldbus length de­
pends on the baud rate used, è section 2.5.2)
Coupling and uncoupling during operation
Cable type
– Reference cable (KURAMO ELECTRIC Co., Ltd.)
– Alternative (DYDEN Corporation)
– Alternative (LEONI protec cable Systems
GmbH)
– Terminating resistor
A.2

Default parameterisation

Note
The following tables contain an overview of parameters of the bus node. The current
and detailed description of all parameters of a CPX terminal are found in the CPX system
description (P.BE-CPX-SYS-...) as well as in the description of each CPX module.
System parameters
Monitoring
– Short circuit/overload in sensor supply (SCS)
– Short circuit/overload at the outputs (SCO)
– Undervoltage at the outputs (U
– Undervoltage at valves (U
– Short circuit at valves (SCV)
Force mode
Defines whether the Force function is blocked glob­
ally or enabled.
System start
Defines the starting reaction of the CPX terminal.
Saves current parameter settings.
Tab. A.1
System parameters
78
CC-Link
Version 1.1 and 2.0
MFP3
0x0177
0x3C
156 kBd, 625 kBd, 2,5 MBd, 5 MBd, 10 MBd
Yes (online-return function, slave station cut-off
function)
Cable specification (è Section 2.5.1)
FANC-110SBH, 20 AWG × 3
CC-110, CC-110-5, CS-110, CM-110-5, 20 AWG × 3
L45467-Y19-C15, 20 AWG × 3
110 Ω / 0.5 W
)
OUT
)
VAL
Function no.
4401
4402
4402
Festo – P.BE-CPX-FB23-24-EN – 1411b – English
Default setting
active
active
active
active
active
blocked
System start with de­
fault parameterisation
(factory setting) and
current CPX expansion.