2
Installation as function module F24
Branch lines
The following table shows the specification for branch lines (without repeater) with the CC-Link refer
ence cable.
Topic
Baud rate
Maximum length of main
string
Max. branch line length
Max. total length of
branch lines
Max. number of parti
cipants per branch line
Connecting cables
Branch line manifold
blocks
Branch line connectors
Distance between
branch lines
Length A
Length B
More than 1 m if only remote I/Os and remote device stations are available.
1)
More than 2 m if local or intelligent device stations are available.
2)
Tab. 2.14 Specification for branch lines
Festo – P.BE-CPX-FB23-24-EN – 1411b – English
Specification
Comments
625 kBd
156 kBd
10 / 5 / 2.5 MBd not possible.
100 m
500 m
Cable length between the terminating resistors
without the length of the branch line cables.
8 m
Total cable length for a branch line.
50 m
200 m
Total cable length for all branch lines.
6 participants per
Total number of connectable participants depends
branch line
on CC-Link specification.
CC-Link reference
CC-Link high-performance cable cannot be used
cable
(e.g. FANC-SBH).
The use of different cables is not possible.
Commercially-avail
Remove as little insulation as possible from the
able branch line
cable when it is connected to the main string.
manifold blocks
Recommended con
nectors for FA
sensors: NECA4202
(IEC 947-5-2) or
compatible
Any
Distance between branch lines (branch line mani
fold blocks or branch line connectors).
< 0.3 m
Cable length between remote I/Os or remote device
stations.
1)
< 1 m
Cable length for master, local and intelligent device
2)
< 2 m
stations as well as the adjoining stations.