USC LPX Operator's Manual page 72

Automated seed treater
Hide thumbs Also See for LPX:
Table of Contents

Advertisement

1. Remove and clean the atomizer
housing.
2. Remove the atomizer head and
stainless steel plumbing. The
atomizer head can be disassembled
(right), for easier cleaning. It is
threaded together and can simply be
unscrewed.
3. Reinstall the atomizer head and
plumbing. Grease the bearing and
spin the atomizer head a few times to
ensure all grease has been worked
into the bearings.
1. Make certain the inside of the tank is completely drained of chemical residue and
thoroughly flush the inside of the tank with clean water.
2. Remove and clean the filter.
3. Pump clean water through all areas of the plumbing including the mix tank, flow
meter, and valves. It may be necessary to move the position of the air actuated
3-way valve from recirc to process in order to clean the chemical lines that run to
the seed treater.
4. Open all drain points, valves, and filter
to let as much of the liquid drain as
possible.
5. If the seed treater will be exposed to
possible freezing temperatures, the final
flush of the system should be made with
an non freezable liquid. Or use
compressed air to blow the lines out
from any moisture.
6. Release pump heads (right) and remove
tubing to prevent any unnecessary
wear.
Page 72
LPX AUTOMATED SEED TREATER
ATOMIZER CHAMBER
LIQUID SYSTEM