LPX AUTOMATED SEED TREATER
H-O-A Button Descriptions
7. INLET CONVEYOR CONTROL MODULE:
This module controls the function of
the inlet conveyor. The HAND button will place the inlet conveyor in the manual mode
of operation. The OFF button will turn the associated device in the OFF mode of
operation. The AUTO button will place the device in the automatic mode of operation.
The motor will not operate in this function unless all other needed devices are in the
AUTO mode and the START button is pressed on the main screen. When the
proximity switch located in the supply hopper above the seed wheel is detecting seed
and the indicator is active, any equipment plugged into the Inlet Conveyor plug will be
turned off.
8. OUTLET CONVEYOR CONTROL MODULE:
This module controls the function of
the outlet conveyor. The HAND button will place the outlet conveyor in the manual
mode of operation. The OFF button will turn the associated device in the OFF mode
of operation. The AUTO button will place the device in the automatic mode of
operation. The motor will not operate in this function unless all other needed devices
are in the AUTO mode and the START button is pressed on the main screen.
9. PUMP CONTROL MODULES:
These modules control the function of the
Pump Stands. The HAND button will place the desired pump in the manual mode of
operation. The OFF button will turn the associated device in the OFF mode of
operation. The AUTO button will place the device in the automatic mode of operation.
The pump will not operate in this function until the START button is pressed on the
main screen. This module also monitors the proximity sensor in the Seed Wheel.
When the proximity switch is detecting seed and the indicator is active, the 3 - way
valve will switch to PROCESS. When no seed is detected it will switch to RECIRC.
10. SCREEN EXIT BUTTON:
This button is used to exit back to the previous screen.
Its functionality is the same throughout the HMI display.
11. AUXILIARY CONTROL:
This module allows the operator to control any unit
which is plugged into the auxiliary port located on the bottom of the automated treater
control panel. The HAND button will allow the user to operate the unit in the manual
mode of operation. The OFF button will disconnect control to the auxiliary port. The
AUTO button will place the unit in the automatic mode of operation. Any unit plugged
into the auxiliary port will not operate in this function until the START button is pressed
on the main screen. It will also turn off using the same logic as the pump stands. See
picture (page 36, top).
Page 35