Output Data Allocation - Omron GX-ID1611 User Manual

Gx-series, ethercat remote i/o terminal ethercat slave units
Table of Contents

Advertisement

9 Encoder Input Slave Unit
Abbreviations used for the counter status information description have the following meanings.
Abbreviation
PACKn
RACKn
EXRESn
EXLAn
EXLBn
CERRn
CRUNn
9-2-2

Output Data Allocation

Encoder Input Slave Unit stores the soft switch and the preset command value as output data, and can
allocate required data to Output area.
The details of each data type are as follows.
Data
Soft switch
Preset command value
9 - 6
Status name
Present value preset
execution completed
Present value internal
reset execution completed
External reset generation
flag
External latch A
generation flag
External latch B
generation flag
Present value preset set
value error
Counter operation state
Size
4 bytes
Used to control the Encoder Input Slave Unit.
Specifies the value to be written over the counter present value data
8 bytes
at preset execution.
Operation
Soft switch "Present value preset execution" completion flag
0→1: Preset execution completed
1→0: Soft switch "Present value preset execution" is set to 0
Soft switch "Present value internal reset execution" completion
flag
0→1: Reset execution completed
1→0: Soft switch "Present value reset execution" is set to 0
1: Turned ON at reset generation by external input/phase Z
0: Soft switch "present value external reset generation flag
clear" is changed from 0 to 1
1: Turned ON with external latch A event generation
0: Soft switch "external latch A generation flag clear" is
changed from 0 to 1
1: Turned ON with external latch B event generation
0: Soft switch "external latch B generation flag clear" is
changed from 0 to 1
0: No setting error
1: Setting error generation
0: Counter stopped
1: Counter operating
Detail