6.6.2 Maintenance test
The anti-panic system (drop-arm) was developed to facilitate the exit of people in
emergencies. Thus, as a preventive measure, we recommend regular tests and
inspections in this device (at least once a month). If the mechanism presents any
defect, request maintenance to a Digicon technician or a qualified company.
Each inspection should carry out the following operational sequence for each of
the three arms:
set the arm on the horizontal position;
turn the turnstile off;
check if the arm drops (if the arm does not drop, contact the dealer or
Digicon);
turn the turnstile on;
raise the arm until it reaches its normal position (the arm must stay in
horizontal position without external support; if it does not, contact the dealer or
Digicon);
repeat the procedure three times for each arm.