Beko METPOINT BDL compact Instructions For Installation And Operation Manual page 12

Hide thumbs Also See for METPOINT BDL compact:
Table of Contents

Advertisement

1)
Input voltage range: 85 ... 264 V AC / 47 ... 63 Hz / 1 Ph. / PE
2)
2
Feeder 3 x 0.75 mm
Cable length 2.5 m, cable type H05VV-F 3G0.75
Connecting lead according to HD21.5, HD21.12 (VDE 0281-5, VDE 0281-12)
The lead complies with EC Regulations No. 1907/2006 (REACH) and No. 2002/95/EC (RoHS), and also with
the EC Low-Voltage-Directive No. 2006/95/EC.
Two-pole plug with a grounding contact
Nominal voltage plug: 250 V
Nominal current plug: 16 A
Manufacturing guideline CEE 7 Standard form VII, VDE 0620
3)
IP 44 in accordance with EN 60529
IP
4
4
4)
Type:
Nominal voltage:
Capacity:
Max. continuous current: 0.2 mA
Diameter:
Height:
Weight:
Operating temperature: -30 ... +60°C
5)
BEKO sensors
Digital BEKO sensors for the pressure dew point with an RS485 interface, series: DPM SD23
Digital BEKO sensors for the dew point and consumption with an SDI interface,
series: DP 109, DP 110, FS 109, FS 211
Analogue BEKO sensors for the pressure, temperature, clip-on ammeter pre-configured
Sensors with analogue signals: 0/4 – 20 mA, 0 - 1/10/30 V, pulse, Pt100, Pt1000
12
with a safety plug and PE protective earthing
International Protection
Protected against the access to dangerous parts with a wire, Ø 1.0 mm
Protected against solid foreign particles with a Ø > 1.0 mm.
Protected against splash water
Lithium manganese dioxide battery, Panasonic CR2032
3 V
225 mAh
20 mm
3.2 mm
2.9 g
Technical data BDL compact
METPOINT® BDL compact