Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual page 53

39mn,mw03-110 series indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

39M UNIT SIZE
CIRCUITING TYPE
Airflow (cfm) at 500 fpm
Total Face Area (sq ft)
Tubes in Face
Tube Length (in.)
No. of Circuits - Total
4-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
6-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
8-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
LEGEND
TXV — Thermostatic Expansion Valve (Field Supplied)
*When 2 nozzle sizes are listed, the smaller nozzle should be located on the upper distrib-
utor.
Table 12 — Direct-Expansion Circuiting Data (cont)
Large Face Area Coils (cont)
58T
Full
Double
28,828
57.7
40
42
40
42
34
81
81
81
81
104
40
42
80
84
34
Upper
Lower
Upper
Lower
Upper
4
4
2
1-3/8
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
E-12/
E-10
C-17
E-10
4
4
2
1-3/8
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
E-12/
E-10
C-17
E-10
4
4
2
1-3/8
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
E-12/
E-10
C-17
E-10
4
4
2
1-3/8
1-3/8
1-5/8
1-1/8
1-1/8
1-3/8
E-12/
E-10
C-17
E-10
4
4
8
8
2
1-3/8
1-3/8
1-3/8
1-3/8
1-5/8
1-1/8
1-1/8
1-1/8
1-1/8
1-3/8
E-12/
E-12/
E-10
E-10
C-17
E-10
E-10
4
4
8
8
2
1-3/8
1-3/8
1-3/8
1-3/8
1-5/8
1-1/8
1-1/8
1-1/8
1-1/8
1-3/8
E-12/
E-12/
E-10
E-10
C-17
E-10
E-10
61W
Full
Double
Full
30,694
61.4
34
34
34
38
104
104
104
108
34
68
68
38
Lower
Upper
Lower
Upper
Lower
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-20
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-20
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-20
2
2
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-20
2
4
4
2
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
C-20
2
4
4
2
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
C-17
C-17
C-17
C-20
NOTE: Factory-supplied distributors have factory-selected nozzle sizes as shown. If necessary,
replace factory-supplied nozzles with field-supplied and field-installed nozzles. Consult
AHUBuilder
®
software selection program for correct nozzle selection.
53
72W
Double
Full
35,625
41,892
71.3
38
38
38
38
38
108
108
108
127
127
38
76
76
38
38
Upper
Lower
Upper
Lower
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-20
C-20
C-20
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-20
C-20
C-20
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-20
C-20
C-20
2
2
2
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
C-20
C-20
C-20
2
4
4
2
2
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-20
C-20
C-20
C-20
C-20
2
4
4
2
2
1-5/8
1-5/8
1-5/8
1-5/8
1-5/8
1-3/8
1-3/8
1-3/8
1-3/8
1-3/8
C-20
C-20
C-20
C-20
C-20
85W
Double
83.8
38
38
127
127
76
76
Upper
Lower
—-
-—
-—
-—
-—
-—
-—
4
4
1-5/8
1-5/8
1-3/8
1-3/8
C-20
C-20
4
4
1-5/8
1-5/8
1-3/8
1-3/8
C-20
C-20