39M UNIT SIZE
CIRCUITING TYPE
Airflow (cfm) at 500 fpm
Total Face Area (sq ft)
Tubes in Face
Tube Length (in.)
No. of Circuits - Total
4-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
6-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
8-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
LEGEND
TXV — Thermostatic Expansion Valve (Field Supplied)
*When 2 nozzle sizes are listed, the smaller nozzle should be located on the upper distribu-
tor.
Table 12 — Direct-Expansion Circuiting Data (cont)
Large Face Area Coils (cont)
25T
Half
Full
12,335
24.7
28
30
28
30
49
49
49
49
14
15
28
30
Upper
Lower
Upper
Lower
Upper
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
C-15
30W
Double
Half
Full
Double
15,174
30.3
28
30
38
38
38
49
49
92
92
92
56
60
19
38
76
Lower
2
2
1-3/8
1-5/8
1-1/8
1-3/8
E-10/E-8
C-20
2
2
1-3/8
1-5/8
1-1/8
1-3/8
E-10/E-8
C-20
2
2
1-3/8
1-5/8
1-1/8
1-3/8
E-10/E-8
C-20
2
2
1-3/8
1-5/8
1-1/8
1-3/8
E-10/E-8
C-20
4
4
2
2
4
1-5/8
1-3/8
1-5/8
1-5/8
1-3/8
1-1/8
1-3/8
1-3/8
C-15
E-10/E-8
C-20
C-20
4
4
2
2
4
1-5/8
1-3/8
1-5/8
1-5/8
1-3/8
1-1/8
1-3/8
1-3/8
C-15
E-10/E-8
C-20
C-20
NOTE: Factory-supplied distributors have factory-selected nozzle sizes as shown. If neces-
sary, replace factory-supplied nozzles with field-supplied and installed nozzles. Consult
AHUBuilder
®
software selection program for correct nozzle selection.
50
30T
Half
Full
14,852
29.7
28
30
28
30
59
59
59
59
14
15
28
30
Upper
Lower
Upper
Lower
Upper
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
C-15
2
2
2
2
1-1/8
1-1/8
1-5/8
1-5/8
1-5/8
7/8
7/8
1-3/8
1-3/8
1-3/8
G-6
G-8/G-6
C-15
C-15
C-15
Double
28
30
59
59
56
60
Lower
4
4
1-5/8
1-3/8
C-15
4
4
1-5/8
1-3/8
C-15