Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual page 159

39mn,mw03-110 series indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

NOMINAL
39M
HEATER
NO. OF
HEATER
COIL
UNIT
AREA
CONTROL
COIL
FACE
SIZE
(sq ft)
STEPS*
kW
VELOCITY
(fpm)
40
50
3
60
80
100
22T
21.18
125
150
6
175
200
230
40
3
50
60
80
100
25W
23.3
125
150
6
175
200
225
250
40
3
50
60
80
100
25T
23.45
125
150
6
175
200
225
250
40
3
50
60
80
100
125
30W
29.3
150
6
175
200
225
250
275
40
3
50
60
80
100
125
30T
29.05
150
6
175
200
225
250
275
60
3
80
100
125
150
35T
34.61
175
6
200
225
250
300
350
LEGEND
AHRI — Air-Conditioning, Heating and
Refrigeration Institute
FLA
— Full Load Amps
*
Standard control steps are listed under the Control Step heading. "Free" additional
steps of control are optionally available when the number of sub-circuits exceeds the
standard number of control steps.
MCA = 1.25 x FLA; for proper wire sizing, refer to Table 310-16 of the NEC (National
Electrical Code).
Table 40 — Electric Heater Data (cont)
208/3/60 VOLTS
TEMP
No.
RISE
Total
FLA MCA†
Sub
MOCP
(F)
Ckt
500
12
111
139
3
150
500
15
139
173
3
175
500
18
167
208
4
225
500
24
222
278
5
300
500
30
278
347
6
350
500
38
500
45
500
53
500
60
500
69
500
11
111
139
3
150
500
14
139
174
3
175
500
16
167
208
4
225
500
22
222
278
5
300
500
27
278
347
6
350
500
34
500
41
500
48
500
55
500
62
500
69
500
11
111
139
3
150
500
14
139
173
3
175
500
16
167
208
4
225
500
22
222
278
5
300
500
27
278
347
6
350
500
34
500
41
500
48
500
54
500
61
500
68
500
9
111
139
3
150
500
11
139
174
3
175
500
13
167
208
3
225
500
17
222
278
3
300
500
22
278
347
3
350
500
27
347
434
3
450
500
33
500
38
500
44
500
49
500
54
500
60
500
11
111
139
3
150
500
14
139
173
3
175
500
16
167
208
4
225
500
22
222
278
5
300
500
27
278
347
6
350
500
34
500
41
500
48
500
54
500
61
500
68
500
75
500
16
167
208
4
225
500
22
222
278
5
300
500
27
278
347
6
350
500
34
500
41
500
48
500
54
500
61
500
68
500
82
500
95
MCA
Minimum Circuit Amps
MOCP
Maximum Overcurrent Protection
240/3/60 VOLTS
480/3/60 VOLTS
No.
Total
Total
FLA MCA†
Sub
MOCP
FLA MCA†
Ckt
96
120
3
125
48
60
120
150
3
175
60
75
144
180
4
200
72
90
192
241
5
250
96
120
241
301
6
350
120
150
150
188
180
226
210
263
241
301
277
346
96
120
3
125
48
60
120
151
3
175
60
75
145
181
4
200
72
90
193
241
5
250
96
120
241
301
6
350
120
151
7
400
151
188
8
500
181
226
9
600
211
263
11
700
241
301
12
700
271
339
13
700
301
376
96
120
3
125
48
60
120
150
3
175
60
75
144
180
4
200
72
90
192
241
5
250
96
120
241
301
6
350
120
150
150
188
180
226
210
263
241
301
271
338
301
376
96
120
3
125
48
75
120
151
3
175
60
90
145
181
4
200
72
96
193
241
5
250
96
120
241
301
6
350
120
151
301
376
7
400
151
188
8
500
181
226
9
600
211
263
11
700
241
301
12
700
271
339
13
700
301
376
14
700
331
414
96
120
3
125
48
60
120
150
3
175
60
75
144
180
4
200
72
90
192
241
5
250
96
120
241
301
6
350
120
150
150
188
180
226
210
263
241
301
271
338
301
376
331
413
144
180
4
200
72
90
192
241
5
250
96
120
241
301
6
350
120
150
150
188
180
226
210
263
241
301
271
338
301
376
361
451
421
526
NOTES:
1.
Subcircuits are internal heater circuits of 48 amps or less.
2.
Electric heat performance is not within the scope of AHRI standard 430 certification.
3.
To avoid damage due to overheating, minimum face velocity cannot fall bellow 350
fpm.
4.
Heaters up to (and including) 60 kW have 3 control steps; beyond 60 k, 6 steps are
standard.
5.
Heater kW offering is controlled by AHUBuilder® program. This table is for reference
only.
159
600/3/60 VOLTS
No.
No.
Total
Total
Sub
MOCP
FLA MCA†
Sub
MOCP
Ckt
Ckt
2
70
38
48
1
50
2
80
48
60
2
70
2
100
58
72
2
80
3
125
77
96
2
100
3
175
96
120
3
125
4
200
120
150
3
175
4
250
144
180
4
200
5
300
168
210
4
225
6
350
192
241
5
250
6
350
221
277
5
300
2
70
39
48
1
50
2
80
48
60
2
70
2
100
58
72
2
80
3
125
77
96
2
100
3
175
96
120
3
125
4
200
120
151
3
175
4
250
145
181
4
200
5
300
169
211
4
225
6
350
193
241
5
250
6
350
217
271
5
300
7
400
241
301
6
350
2
70
38
48
1
50
2
80
48
60
2
70
2
100
58
72
2
80
3
125
77
96
2
100
3
175
96
120
3
125
4
200
120
150
3
175
4
250
144
180
4
200
5
300
168
210
4
225
6
350
192
241
5
250
6
350
217
271
5
300
7
400
241
301
6
350
2
70
39
48
1
50
2
80
48
60
2
70
2
100
58
72
2
80
3
125
77
96
2
100
3
175
96
120
3
125
4
200
120
151
3
175
4
250
145
181
4
200
5
300
169
211
4
225
6
350
193
241
5
250
6
350
217
271
5
300
7
400
241
301
6
350
7
450
265
331
6
350
2
70
38
48
1
50
2
80
48
60
2
70
2
100
58
72
2
80
3
125
77
96
2
100
3
175
96
120
3
125
4
200
120
150
3
175
4
250
144
180
4
200
5
300
168
210
4
225
6
350
192
241
5
250
6
350
217
271
5
300
7
400
241
301
6
350
7
450
265
331
6
350
2
100
58
72
2
80
3
125
77
96
2
100
3
175
96
120
3
125
4
200
120
150
3
175
4
250
144
180
4
200
5
300
168
210
4
225
6
350
192
241
5
250
6
350
217
271
5
300
7
400
241
301
6
350
8
500
289
361
7
400
9
600
337
421
8
450
380/3/50 VOLTS
No.
FLA MCA†
Sub
MOCP
Ckt
61
76
2
80
76
95
2
100
91
114
2
125
122
152
3
175
152
190
4
200
190
237
4
250
228
285
5
300
266
332
6
350
304
380
7
400
349
437
8
450
61
76
2
80
76
95
2
100
91
114
2
125
122
152
3
175
152
190
4
200
190
238
4
250
228
285
5
300
266
333
6
350
304
380
7
400
61
76
2
80
76
95
2
100
91
114
2
125
122
152
3
175
152
190
4
200
190
237
4
250
228
285
5
300
266
332
6
350
304
380
7
400
342
427
8
450
380
475
8
500
61
76
2
80
76
91
2
100
91
122
3
125
122
152
3
175
152
190
4
200
190
238
4
250
228
285
5
300
266
333
6
350
304
380
7
400
61
76
2
80
76
95
2
100
91
114
2
125
122
152
3
175
152
190
4
200
190
237
4
250
228
285
5
300
266
332
6
350
304
380
7
400
342
427
8
450
380
475
8
500
91
114
2
125
122
152
3
175
152
190
4
200
190
237
4
250
228
285
5
300
266
332
6
350
304
380
7
400
342
427
8
450
380
475
8
500