Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual page 157

39mn,mw03-110 series indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

NOMINAL
39M
HEATER
NO. OF
HEATER
COIL
UNIT
AREA
CONTROL
COIL
FACE
SIZE
(sq ft)
STEPS*
kW
VELOCITY
(fpm)
5
500
10
500
15
500
20
500
03W
3
3
25
500
30
500
35
500
10
500
15
500
20
500
06W
5.2
3
30
500
40
500
50
500
60
500
10
500
20
500
30
500
3
40
500
07T
7.13
50
500
60
500
70
500
6
80
500
20
500
30
500
3
40
500
08W
7.4
50
500
60
500
70
500
6
80
500
20
500
30
500
40
500
3
50
500
60
500
7.61
09T
70
500
80
500
6
90
500
100
500
20
500
30
500
3
40
500
50
500
10W
9.9
60
500
75
500
6
90
500
100
500
20
500
30
500
40
500
3
50
500
60
500
70
500
11T
10.26
80
500
90
500
100
500
6
110
500
120
500
130
500
LEGEND
AHRI
— Air-Conditioning, Heating and
Refrigeration Institute
FLA
— Full Load Amps
*Standard control steps are listed under the Control Step heading. "Free" additional steps of control
are optionally available when the number of sub-circuits exceeds the standard number of control
steps.
†MCA = 1.25 x FLA; for proper wire sizing, refer to Table 310-16 of the NEC (National Electrical
Code).
NOTES:
Table 40 — Electric Heater Data
208/3/60 VOLTS
TEMP
No.
RISE
Total
Total
FLA MCA†
Sub
MOCP
FLA MCA†
(F)
Ckt
11
14
17
1
20
12
21
28
35
1
35
24
32
42
52
1
60
36
43
56
69
2
70
48
53
69
87
2
90
60
64
83
104
2
110
72
75
97
122
3
125
84
12
28
35
1
35
24
18
42
52
1
60
36
25
56
69
2
70
48
37
83
104
2
110
72
49
111
139
3
150
96
61
139
174
3
175
120
74
167
208
4
225
145
9
28
35
1
35
24
18
56
69
2
70
48
27
83
104
2
110
72
36
111
139
3
150
96
45
139
173
3
175
120
54
167
208
3
225
144
63
194
243
3
250
168
72
17
56
69
2
70
48
26
83
104
2
110
72
35
111
139
3
150
96
43
139
174
3
175
120
52
167
208
4
225
145
60
195
243
5
250
169
69
222
278
5
300
193
17
56
69
2
70
48
25
83
104
2
110
72
34
111
139
3
150
96
42
139
173
3
175
120
50
167
208
3
225
144
59
194
243
3
250
168
67
222
278
3
300
192
76
250
312
3
350
217
84
13
56
69
2
70
48
19
83
104
2
110
72
26
111
139
3
150
96
32
139
174
3
175
120
39
167
208
4
225
145
48
208
261
5
300
181
58
250
313
6
350
217
65
278
347
6
350
241
12
56
69
2
70
48
19
83
104
2
110
72
25
111
139
3
150
96
31
139
173
3
175
120
37
167
208
3
225
144
44
194
243
3
250
168
50
222
278
3
300
192
56
250
312
3
350
217
62
278
347
3
350
241
68
75
81
MCA
Minimum Circuit Amps
MOCP
Maximum Overcurrent Protection
240/3/60 VOLTS
480/3/60 VOLTS
No.
No.
Total
Sub
MOCP
FLA MCA†
Sub
Ckt
Ckt
15
1
20
6
8
1
30
1
35
12
15
1
45
1
50
18
23
1
60
2
70
24
30
1
75
2
80
30
38
1
90
2
100
36
45
1
105
2
110
42
53
1
30
1
35
12
15
1
45
1
50
18
23
1
60
2
70
24
30
1
90
2
100
36
45
1
120
3
125
48
60
2
151
3
175
60
75
2
181
4
200
72
90
2
30
1
35
12
15
1
60
2
70
24
30
1
90
2
100
36
45
1
120
3
125
48
60
2
150
3
175
60
75
2
180
3
200
72
90
2
210
3
225
84
105
2
-—
96
120
3
60
2
70
24
30
1
90
2
100
36
45
1
120
3
125
48
60
2
151
3
175
60
75
2
181
4
200
72
90
2
211
4
225
84
105
2
241
5
250
96
120
3
60
2
70
24
30
1
90
2
100
36
45
1
120
3
125
48
60
2
150
3
175
60
75
2
180
3
200
72
90
2
210
3
225
84
105
2
241
3
250
96
120
3
271
3
300
108
135
3
120
150
3
60
2
70
24
30
1
90
2
100
36
45
1
120
3
125
48
60
2
151
3
175
60
75
2
181
4
200
72
90
2
226
4
250
90
113
2
271
5
300
108
135
3
301
6
350
120
151
3
60
2
70
24
30
1
90
2
100
36
45
1
120
3
125
48
60
2
150
3
175
60
75
2
180
3
200
72
90
2
210
3
225
84
105
2
241
3
250
96
120
3
271
3
300
108
135
3
301
3
350
120
150
3
132
165
3
144
180
3
156
195
3
1.
Subcircuits are internal heater circuits of 48 amps or less.
2.
Electric heat performance is not within the scope of AHRI standard 430 certification.
3.
To avoid damage due to overheating, minimum face velocity cannot fall bellow 350
fpm.
4.
Heaters up to (and including) 60 kW have 3 control steps; beyond 60 k, 6 steps are
standard.
5.
Heater kW offering is controlled by AHUBuilder® program. This table is for reference
only.
157
600/3/60 VOLTS
380/3/50 VOLTS
No.
Total
Total
MOCP
FLA MCA†
Sub
MOCP
FLA MCA†
Ckt
20
5
6
1
20
8
20
10
12
1
20
15
25
14
18
1
20
23
35
19
24
1
25
30
40
24
30
1
35
38
50
29
36
1
40
46
60
34
42
1
45
53
20
10
12
1
20
15
25
14
18
1
20
23
35
19
24
1
25
30
50
29
36
1
40
46
70
39
48
1
50
61
80
48
60
2
70
76
100
58
72
2
80
91
20
10
12
1
15
15
35
19
24
1
25
30
50
29
36
1
40
46
70
38
48
1
50
61
80
48
60
2
70
76
100
58
72
2
80
91
110
67
84
2
90
106
125
122
35
19
24
1
25
30
50
29
36
1
40
46
70
39
48
1
50
61
80
48
60
2
70
76
100
58
72
2
80
91
110
67
84
2
90
106
125
77
96
2
100
122
35
19
24
1
25
30
50
29
36
1
40
46
70
38
48
1
50
61
80
48
60
2
70
76
100
58
72
2
80
91
110
67
84
2
90
106
125
77
96
2
100
122
150
87
108
2
110
137
175
96
120
3
125
35
19
24
1
25
30
50
29
36
1
40
46
70
39
48
1
50
61
80
48
60
2
70
76
100
58
72
2
80
91
125
72
90
2
100
114
150
87
108
2
110
137
175
96
120
3
125
152
35
19
24
1
25
30
50
29
36
1
40
46
70
38
48
1
50
61
80
48
60
2
70
76
100
58
72
2
80
91
110
67
84
2
90
106
125
77
96
2
100
122
150
87
108
2
110
137
175
96
120
3
125
152
175
106
132
3
150
167
200
115
144
3
150
182
200
125
156
3
175
198
No.
Sub
MOCP
Ckt
10
1
20
19
1
20
29
1
30
38
1
40
48
1
50
57
1
60
67
2
70
19
1
20
29
1
30
38
1
40
57
1
60
76
2
80
95
2
100
114
2
125
19
1
20
38
1
40
57
1
60
76
2
80
95
2
100
114
2
125
133
3
150
152
3
175
38
1
40
57
1
60
76
2
80
95
2
100
114
2
125
133
3
150
152
3
175
38
1
40
57
1
60
76
2
80
95
2
100
114
2
125
133
3
150
152
3
175
171
3
175
38
1
40
57
1
60
76
2
80
95
2
100
114
2
125
143
3
150
171
3
175
190
4
200
38
1
40
57
1
60
76
2
80
95
2
100
114
2
125
133
3
150
152
3
175
171
3
175
190
3
200
209
3
225
228
3
250
247
3
250