Large Face Area Coils - Carrier Aero 39MN Series Installation, Start-Up And Service Instructions Manual

39mn,mw03-110 series indoor and weathertight outdoor air handlers
Table of Contents

Advertisement

39M UNIT SIZE
CIRCUITING TYPE
Airflow (cfm) at 500 fpm
Total Face Area (sq ft)
Tubes in Face
Tube Length (in.)
No. of Circuits - Total
4-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
6-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
8-Row Coil
Face Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Intertwined Row Split Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
Single Circuit Coils
No. of TXVs
Suction Connections (in. OD)
Distributor Connections (in. OD)
Distributor Nozzle Size
LEGEND
TXV — Thermostatic Expansion Valve (Field Supplied)
*When 2 nozzle sizes are listed, the smaller nozzle should be located on the upper
distributor.
Table 12 — Direct-Expansion Circuiting Data (cont)

Large Face Area Coils

03W
06W
Quarter
Half
Quarter
Half
Full
1,736
2,951
3.5
5.9
20
20
20
20
20
20
20
34
34
34
4
10
4
10
20
2
2
2
2
7
/
1-1/8
7
/
1-1/8
8
8
7
7
7
7
/
/
/
/
8
8
8
8
G-1.5
G-3
G-1.5
G-3
2
2
2
2
7
7
/
1-1/8
/
1-1/8
8
8
7
/
7
/
7
/
7
/
8
8
8
8
G-1.5
G-3
G-1.5
G-3
1
1
1
1
1-1/8
1-3/8
1-1/8
1-3/8
7
7
/
1-1/8
/
1-1/8
8
8
G-3
E-10
G-3
E-10
2
2
2
2
7
/
1-1/8
7
/
1-1/8
8
8
7
/
7
/
7
/
7
/
8
8
8
8
G-1.5
G-3
G-1.5
G-3
2
2
2
2
7
/
1-1/8
7
/
1-1/8
8
8
7
7
7
7
/
/
/
/
8
8
8
8
G-1.5
G-3
G-1.5
G-3
1
1
1
1
1-1/8
1-3/8
1-1/8
1-3/8
7
/
1-1/8
7
/
1-1/8
8
8
G-3
E-10
G-3
E-10
2
2
1-1/8
1-1/8
1-3/8
7
7
/
/
1-1/8
8
8
G-3
G-3
E-10
2
2
1-1/8
1-1/8
1-3/8
7/8
7
/
1-1/8
8
G-3
G-3
E-10
1
1
1-3/8
1-3/8
1-1/8
1-1/8
E-10
E-10
07T
Quarter
Half
Full
Double
3,837
7.7
34
34
34
34
26
26
26
26
9
17
34
68
2
2
2
1-1/8
1-3/8
1-5/8
7/8
1-1/8
1-3/8
G-3/G-2.5
E-8
C-17
2
2
2
1-1/8
1-3/8
1-5/8
7
/
1-1/8
1-3/8
8
G-3/G-2.5
E-8
C-17
1
1-3/8
1-1/8
E-8
2
2
1-3/8
1-5/8
1-1/8
1-3/8
E-8
C-17
2
2
1-3/8
1-5/8
1-1/8
1-3/8
E-8
C-17
2
2
2
4
1-3/8
1-5/8
1-5/8
1-1/8
1-3/8
1-3/8
E-8
C-17
C-17
2
2
2
4
1-3/8
1-5/8
1-5/8
1-1/8
1-3/8
1-3/8
E-8
C-17
C-17
NOTE: Factory-supplied distributors have factory-selected nozzle sizes as shown. If neces-
sary, replace factory-supplied nozzles with field-supplied and installed nozzles. Consult
AHUBuilder
®
software selection program for correct nozzle selection.
46
08W
Quarter
Half
Full
Quarter
Half
3,819
7.6
22
22
22
36
36
40
40
40
29
29
6
11
22
9
18
2
2
2
2
7
/
1-1/8
-—
1-1/8
1-3/8
8
7
7
7
/
/
/
1-1/8
8
8
8
G-2
G-4 / G-3
G-3 /G-2.
E-8
2
2
-—
2
2
7
/
1-1/8
-—
1-1/8
1-3/8
8
7
/
7
/
7
/
1-1/8
8
8
8
G-2
G-4/G-3
G-3/G-2.5
E-8
1
1
-—
1
1-1/8
1-3/8
1-3/8
7
/
1-1/8
1-1/8
8
G-4
E-12
E-8
2
2
2
2
7
/
1-1/8
1-3/8
1-3/8
8
7
/
7
/
1-1/8
1-1/8
8
8
G-2
G-4 / G-3
E-12
E-8
2
2
2
2
7
/
1-1/8
1-3/8
1-3/8
8
7
7
/
/
1-1/8
1-1/8
8
8
G-2
G-4 / G-3
E-12
E-8
1
1
1-1/8
1-3/8
7
/
1-1/8
8
G-4
E-12
2
2
2
1-1/8
1-3/8
1-3/8
7
/
1-1/8
1-1/8
8
G-4 / G-3
E-12
E-8
2
2
2
1-1/8
1-3/8
1-3/8
7
/
1-1/8
1-1/8
8
G-4 / G-3
E-12
E-8
1
1-3/8
1-1/8
E-12
09T
Full
Double
4,531
9.1
36
36
29
29
36
72
2
1-5/8
1-3/8
C-17
2
1-5/8
1-3/8
C-17
2
1-5/8
1-3/8
C-17
2
1-5/8
1-3/8
C-17
2
4
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-17
2
4
1-5/8
1-5/8
1-3/8
1-3/8
C-17
C-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents