Gprs Options; Interactive Options - DSC GS2060-SM Installation Manual

Alarm communicator, gprs cellular communicator, ethernet/internet communicator, ethernet/internet and gprs dual-path communicator
Table of Contents

Advertisement

GPRS Options

[221] GPRS Public Access Point Name
Default ( )
When the Communicator is operating on a private APN, use this Section to select a public APN for DLS and
Remote Firmware Update. This information is available from your network carrier. The APN identifies the public
GPRS network that the Communicator will connect to.
[222] GPRS Login User Name
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Program your login
User name here. Format is up to 32 ASCII characters.
NOTE: This Section is not accessible via PC1616/PC1832/PC1864 keypad programming.
[223] GPRS Login Password
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Program your login
password here.
Format is up to 32 ASCII characters.
[224] GPRS Test Transmission Time of Day
Default (9999)
Enter a 4 digit value using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid range:
00-23 for the hours (HH) and 00-59 for the minutes (MM).
NOTE: To disable the test transmission time of day enter 9999 or FFFF in this Section.
The internal date and time will be automatically programmed by the primary receiver only.
[225] GPRS Test Transmission Cycle
Default (000000)
This value represents the interval in between test transmissions in minutes. Valid range: 000000 - 999999 minutes.
Once the unit has sent the initial periodic test transmission, all future test transmissions will be offset by the pro-
grammed number of minutes. See Sections [026 - 029].
Test Transmission Interval
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will dis-
able test transmission.
[226] GSM Trouble Delay
Default (00)
This option is used to program the delay, in minutes, for reporting a GSM Trouble Delay. Valid entries are 00 - FF.
(e.g., for a 10 minute GSM Trouble Delay enter: 0A). There is no delay if value is programmed as 00.

Interactive Options

(TL260-SM/TL260GS-SM Only)
[651] Interactive Account Code
Default (MAC or IMEI)
This section is programmed as 2 field by 6 hexadecimal number. Valid range for each field is 000000 ~ FFFFFF.
The IMEI can be viewed in Section [997]. The MAC address can be viewed in Section [998].
[652] Interactive Access Code
Default (1234)
This section is programmed with the hexadecimal interactive access code. Valid range is 0000 ~ FFFF.
[653] Interactive IP Address
Default (000.000.000.000)
This section is programmed as with the IP address of the Interactive Server. Format is 4 fields, each field is a 3
digit decimal. Valid range: 000-255].
[654] Interactive Remote Port
Default (0BFC/3068)
This Section is used to program the port number used by Interactive. Set the value of this port when your installa-
tion is located behind a firewall, and must be assigned a particular port number as determined by your central sta-
tion system administrator. Valid range: 0000 - FFFF.
[655] Interactive Local Port
Default (0BFD/3069)
Use this Section to set the value of the Interactive local outgoing port. Set the value of this port when your installa-
tion is located behind a firewall and must be assigned a particular port number as determined by your central sta-
tion system administrator. Valid range: 0000 - FFFF.
[656] Interactive Domain Name
Default ( )
Enter the Interactive Domain Name as 32 ASCII characters.
Programming this Section is not permitted on a UL/ULC listed system.
[657] Interactive Incoming Port
Default (0BFE/3070)
The Interactive Incoming Local Port (listening port) is the port Interactive will use when connecting to the Communi-
cator. If a router or gateway is used, it must be programmed with a Transmission Control Protocol (TCP) port for-
ward for this port to the Communicator module IP address. Valid range: 0000-FFFF.
Table 11: Ethernet Test Transmission Interval
Programmed Minutes
Daily
Weekly
001440
010080
22
Monthly
043200

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl260-smTl260gs-sm

Table of Contents