Keybus Connection for ADT Pulse
4. Install the Keybus cable as follows:
WARNING: D
NOT
O
THE
a. Attach a wire from the Communicator YEL terminal to the panel YEL terminal.
b. Attach a wire from the Communicator GRN terminal to the panel GRN terminal.
RS-422 Connection for ADT Pulse
At the Communicator inside the Panel, attach the previously run cable as follows:
1. Securely fasten the TX+ wire to RX+ on the terminal block.
2. Securely fasten the TX- wire to RX- on the terminal block.
3. Securely fasten the RX+ wire to TX+ on the terminal block.
4. Securely fasten the RX- wire to TX- on the terminal block.
5. Securely fasten the GND wire on the terminal block .
NOTE: The GND connection is optional, DSC recommends connecting GND at both ends of cable.
K
CONNECT
EYBUS
C
T
OMMUNICATOR
ERMINAL
R
B
ED OR
LK WIRES TO THE
B
.
LOCKS
8
Figure 3 Communicator Wiring Diagram
DG009546