The Programming Sections in this document are accessed via panel Section for Ethernet/GPRS Programming.
Enter: [*][8][installer code][851][# ##], Where # ## is the 3 digit Section number referenced in this document.
The Programming Worksheets at the end of this document can be used to record the new values when pro-
gramming changes have been made from the default values. Default values are provided for each Section.
Programming Sections cannot be modified from the keypad. Installers may review/record programming Options
at the keypad.
NOTE: Ethernet/GPRS Programming Sections accessed through the keypad are for display purposes
only. Configuration changes must be done remotely. Specified panel Sections must be configured for
proper operation of the Communicator and the Panel.

System Options

[001] Ethernet IP Address
Default (000.000.000.000)
Enter the IP address of the Communicator. Ensure that the IP address is unique to your Communicator on the local
network. Format is 4 fields, each field is a 3 digit decimal number. Valid range: 000-255. If an IP address is pro-
grammed in this Section, the unit will operate with Static IP (DHCP disabled). Sections [002] and [003] must also be
programmed when using Static IP addresses.
NOTE: Default for this Section is Dynamic Host Configuration Protocol (DHCP) enabled. When enabled,
the DHCP Server will set values for: IP Address [001], Subnet Mask [002], and Gateway [003]. Program-
ming an IP address in this Section will disable DHCP (Static IP).
[002] Ethernet IP Subnet Mask
Default (255.255.255.000)
Enter the Ethernet IP Subnet Mask of the dual Communicator. Format is 4 fields, each field is a 3 digit decimal
number. Valid range: 000-255.
NOTE: If DHCP is enabled, the DHCP Server will assign the subnet mask for this Section and the
programmed value will be ignored.
[003] Ethernet Gateway IP Address
Default (000.000.000.000)
Enter the Ethernet Gateway IP address of the Communicator. The gateway IP address is required when a router is
used on the local network to reach the destination IP address specified in Section [001]. Format is 4 fields, each
field is a 3 digit decimal number. Valid range: 000-255.
NOTE: If DHCP is enabled, the DHCP Server will assign the Gateway IP address for this Section and the
programmed value will be ignored.
[004] Receiver Supervision Interval
Default (0087/135)
When receiver supervision is enabled (ON) in Section [005] Toggle Option [3], the unit sends heartbeats to Ethernet
Receiver 1 or GPRS Receiver 1 to test the communications path. Use this Section to set the interval time (in sec-
onds) when heartbeats will be sent. Valid range 000A-FFFF seconds. If the programmed value is less than
(000A/10) seconds, supervision is disabled.
Jurisdiction
UL Commercial Burglary
UL Residential Fire
UL Residential Burglary
ULC Commercial Burglary Active
ULC Commercial Burglary Passive
ULC Commercial Fire Active
ULC Commercial Fire Passive
Receiver Window: This is the supervision timeout that must be configured at the central station receiver.
Recommended Values: This is the recommended heartbeat interval that should be programmed into the
Communicator.
For ULC passive systems (not using heartbeat supervision), the Daily test transmission must be enabled
over each available communication channel Sections [125] and [225]. When programming with Connect24,
the recommended intervals will be programmed automatically when the required window is selected.
[005] System Toggle Options
[1] Ethernet Receiver 1 Supervised
Default (OFF) (TL260-SM/TL260GS-SM only).
ON: Ethernet Receiver 1 will be supervised and heartbeats will be sent to Ethernet Receiver 1 based on the
supervision interval programmed in Section [004].
OFF: Ethernet Receiver 1 will not be supervised. When disabled, heartbeat 1 is sent to the Ethernet receiver
once every hour, regardless of supervision type (heartbeat 1 or 2). The heartbeat is resent every 5 seconds until
ACK. If no event or heartbeat ACK is received after (Receiver Supervision Interval + 75 seconds), Supervisory
trouble is indicated.
NOTE: Ethernet Receiver 2 can not be supervised.
[2] GPRS Receiver 1 Supervised
Default (OFF)
ON: GPRS Receiver 1 will be supervised and heartbeats will be sent to GPRS Receiver 1 based on the super-
vision interval programmed in Section [004]. If ACK to heartbeat is not received, it is retransmitted every 5 sec-
onds. Failure to ACK 2 consecutive heartbeats will reset the radio.

COMMUNICATOR PROGRAMMING SECTIONS

Table 6: Supervision Intervals for UL/ULC
Receiver Window
(Timeout)
200 seconds
30 days
30 days
180 seconds
24 hours
180 seconds
24 hours
14
Recommended Supervision Interval
(0087/135) seconds
Panel Test Transmission
Panel Test Transmission
(005A/90) seconds
Panel Test Transmission
(0073/115) seconds
Panel Test Transmission