a. Attach one end of the PC-LINK cable to the panel PC-LINK header on the panel (red wire goes on Pin 1
of the panel PC-LINK header).
b. Insert the assembled Communicator into the panel.
NOTE: Ensure that the threaded antenna connection
point is visible through the knockout hole at the top
right of the panel.
c. TL260-SM/TL260GS-SM only: Place the nylon
washer with bushing (thick flat washer) onto the
threaded section of the antenna cable. Insert the
threaded section through the antenna mounting
knockout hole at top right of panel.
d. Place the second nylon washer (flat), followed by the
brass washer and the brass nut, onto the threaded
section of the cable, outside the panel. Tighten the
assembly by hand only. (Finger Tight - Do not over-
tighten the assembly).
e. Locate the screw hole on the right side wall of the
panel. See Figure 2 (screw). Line up the assembled
Communicator with the side wall of the panel and,
using the screw provided, secure the mounting
bracket to the panel.
f. Attach the other end of the PC-LINK cable to the
Communicator (black wire goes on Pin 1 of the Com-
municator).
g. TL260-SM/TL260GS-SM only: Using light pressure
(finger tight), attach the supplied 5" white quad band
whip antenna to the threaded antenna connection
point at top of the panel.
WARNING!
GS2060-SM/TL260-SM/TL260GS-SM
WIRING OVER THE CIRCUIT BOARD
CIRCUIT BOARD AND WIRING
ALL POINTS BETWEEN NON
3.To electrically connect the Communicator to the panel, perform the following steps (See Figure 3).
a. Disconnect both AC power and battery connections from the panel.
Module Power Connection
b. Attach a wire from the Communicator's left PWR terminal to the panel's BELL+ terminal.
NOTE: For ULC Commercial Fire Monitoring applications: Do NOT connect any devices on the
Bell + terminal other than the Communicator.
c. Attach a wire from the Communicator's GND terminal (beside PWR) to the panel's AUX - terminal.
d. Attach a wire from the Communicator's SHLD terminal to the panel's EGND terminal.
(Protective earth ground).
(Optional) External Bell/Siren Connection
e. Attach a wire from the Communicator's right PWR terminal to the positive (+) terminal on the Bell/Siren.
f. Attach the panel's BELL
NOTE: If a Bell/Siren is not used, install the 1K
with the panel) between the panel's Bell + and Bell - terminals, then only wire the BELL + to the PWR
terminal on the Communicator.
g. Confirm that the SIM card is inserted in the holder and locked.
h. Insert the PC-LINK connector into the Communicator's PC-LINK socket. (Black wire on Pin 1 on the
Communicator).
MODULES ARE POWER LIMITED
. M
AINTAIN AT LEAST
. A
¼
MINIMUM OF
-
POWER LIMITED WIRING AND POWER LIMITED WIRING
-
terminal to the negative (
Figure 2 PC1616/1832/1864 Control Panel
PC-Link
Cable Connector
PC1616/1832/1864
1
. (25.4
IN
. (7
)
IN
MM
SEPARATION MUST BE MAINTAINED AT
-
) terminal on the Bell/Siren.
½W 5% resistor (Brown, Black, Red, Gold) (supplied
7
Quad band
Whip Antenna
Use light pressure
to attach antenna
Finger Tight
GSM Radio
RJ-45
. D
O NOT ROUTE ANY
)
MM
SEPARATION BETWEEN
.
only.
(screw)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl260-smTl260gs-sm

Table of Contents