6.
Troubleshooting
Check List
2
Connect the mini SAS HD cable between enclosures while the drive enclosure is on.
3
Press the controller enclosure's Power switch to turn on the ETERNUS DX.
When the l (IN) and n (OUT) sides of the mini SAS HD cable between enclosures are incorrectly connected
or the cable is connected in the wrong order
1
Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX, and turn
off the AC power.
2
Reconnect the mini SAS HD cable between enclosures.
3
Make sure that AC power is being supplied, then turn the ETERNUS DX on.
When the FAULT LED Blinks
Check the general status and the system messages in ETERNUS Web GUI. A general status of
that the ETERNUS DX contains a component that requires preventive maintenance.
In the details screen for each component, check the detailed information for each component with the
bol and contact your maintenance engineer.
For details about how to check the general status via ETERNUS CLI, refer to
CLI" (page
44).
When the DRIVE FAULT LED Is On
Check the drive status.
While the Protection (Shield) function is being used, the DRIVE FAULT LED is temporarily turned on. For details
on how the Protection (Shield) function works and how to check whether it is running, refer to "Design Guide
(Basic)".
If the problem persists, contact your maintenance engineer.
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic)
80
Copyright 2018 FUJITSU LIMITED
indicates
"Displaying Status via ETERNUS
P3AM-9012-08ENZ0