4.
Component Expansion/Function Enhancement
Installing Additional Drive Enclosures
The FAULT LED for the DI (IN) port to which the cable is to be connected and the LINK/FAULT LED for the DI
(OUT) port blink on and off.
Drive enclosure 2
(drive enclosure
that is to be added)
Drive enclosure 1
Controller enclosure
14
Click the [Next >>] button.
The [Enable IOM#1] screen appears.
15
Connect the DI (OUT) port of IOM#1 in the drive enclosure that is to be added to the DI (IN) port of IOM#1
in the drive enclosure that is nearest to the drive enclosure that is to be added with the mini SAS HD cable
between enclosures.
The following figure shows how a mini SAS HD cable between enclosures (DE and DE) is connected when
drive enclosure 2 is added.
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic)
Connect here
Connect here
67