6.
Troubleshooting
Check List
When the ETERNUS DX Refuses to Turn On
Check the points that are shown below. If the problem cannot be resolved, leave the ETERNUS DX alone and
contact your maintenance engineer.
Is the ETERNUS DX's power cord disconnected?
Is PSU switch of the power supply unit turned to OFF (¡)?
Is the main line switch of the power distribution unit turned OFF (¡)?
Is there a power failure?
Is the mini SAS HD cable between enclosures disconnected?
When the READY LED Is Not On
If more than 10 minutes have passed since the power of the ETERNUS DX was turned on and the READY LED is
still not on, contact your maintenance engineer.
When the FAULT LED Is On
Check the general status and the system messages in ETERNUS Web GUI. Perform the necessary actions to cor-
rect the problem. If the problem cannot be resolved, leave the ETERNUS DX alone and contact your maintenance
engineer.
For details about how to check the general status via ETERNUS CLI, refer to
CLI" (page
44).
When the general status of ETERNUS Web GUI is
Check whether one side of the mini SAS HD cable between enclosures is disconnected. If so, install the con-
-
nector in the DI port.
Check if the mini SAS HD cable between enclosures is connected. If the mini SAS HD cable between enclo-
-
sures is not connected, use the following procedure to connect the mini SAS HD cable between enclosures.
-
Check that the l (IN) and n (OUT) side of the mini SAS HD cable between enclosures is connected correctly.
If the mini SAS HD cable between enclosures is connected incorrectly, use the procedure that is shown below
to reconnect it.
When the general status of ETERNUS Web GUI is
Check whether the mini SAS HD cable between enclosures is connected in the correct order or check that the l
(IN) and n (OUT) side of the mini SAS HD cable between enclosures is connected correctly. If the mini SAS HD
cable between enclosures is not connected correctly, use the procedure that is shown below to reconnect the
mini SAS HD cable between enclosures.
When a mini SAS HD cable between enclosures is not connected
1
Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX.
Drive enclosures with no mini SAS HD cable between enclosures connected will remain on.