Mounting Laser Pointer - EFD Ultra 325TT User Manual

Ultra tt automation series
Table of Contents

Advertisement

®
A NORDSON COMPANY
2.6

MOUNTING LASER POINTER

Some customers may prefer to use a laser pointer to aid in positioning the X or Y dispense
programming points. Note that the laser pointer should be used in conjunction with the height
sensor. The height sensor, along with the dot/line parameter setting of the "dispense gap" will
determine the z-height at the dispense point. EFD provides a laser pointer and bracket (#700820)
that can be easily mounted onto the Ultra TT.
To connect the optional laser pointer teaching device to the Ultra TT:
1.
Secure the laser to the Z-head by sandwiching the laser
bracket behind the syringe or valve bracket. Connect the
laser pointer's red wire to terminal pin #6 (+5VDC power
supply) on the Z-head connecter and the blue wire to
terminal #9.
2.
Next, check the functionality of the laser.
a.
Using the PDA, select "Program" from the "Main"
screen.
b.
Tap the top left-hand corner of the Program screen
and select "Util" from the menu bar.
c.
Select "Toggle Laser". This will turn the laser pointer
drive on. To turn the laser pointer off, select "Toggle
Laser" again.
Note: the laser should be turned off when not in use to extend
the life of the laser and to prevent accidental exposure.
Ultra TT User's Guide
Version 1.2
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultra 525tt

Table of Contents