Page 1
™ LTIMUS High Precision Dispenser ™ Electronic pdf files of EFD manuals are also available at www.efd-inc.com www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide .
Page 2
Thank You! You have just purchased the world’s finest dispensing equipment. I want you to know that all of us at EFD value your business and will do everything in our power to make you a satisfied customer. If at any time you are not fully satisfied with our equipment or the support provided by your EFD Product Application Specialist, please contact me personally at 800.556.3484 (US),...
Warranty ........... . . Back Cover www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Product Safety Statement EFD PRODUCT SAFETY STATEMENT This statement provides personal and equipment safety notices for EFD dispensing products excluding the TT dispensing robot. For the safety statement on the TT dispensing robot, please see the TT user’s guide. WARNING The safety message that follows has a WARNING level hazard.
Page 5
Qualified Personnel Equipment owners are responsible for making sure that EFD equipment is installed, operated and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks.
Page 6
• Test – Verify operation of features and performance of equipment using the appropriate sections of this user guide. A faulty or defective unit should be returned to EFD or representative for refurbishment. • Use only replacement parts that are designed for use with original equipment.
Page 7
Identify the reason for the malfunction and correct it before restarting the system. • For EFD air-powered dispensers, remove the syringe barrel from the adapter assembly. For EFD electro-mechanical dispensers, slowly unscrew the barrel retainer and remove the barrel from the actuator.
Humidity: 85%RH at 30°C noncondensing Approvals: RoHS, WEEE & China RoHS Compliant, CE www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
D-sub I/O (15-pin) and communication (9-pin) connections • Alarm input/output I/O signals www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
The Dispenser UNPACKING THE DISPENSER Unpack the contents of the package and lay them out on a clean workbench. The following items should be included with your Ultimus V dispenser: Tubing-6mm OD Blue Urethane Connector 15 Pos Plug D-Sub Solder...
ESD Jack Front Panel Power Switch: Turns the Ultimus V dispenser on and off. RS-232 Connector: Allows all dispensing parameters to be modified from a remote PC or PLC. LCD Display: Shows data and system status as well the current function selected.
Page 12
Foot Pedal/Finger Switch Connector: Connection for dispenser actuating device. Connection is for a momentary contact closure switching device. EFD strongly suggests the use of EFD foot pedals and finger switches, which are specifically designed for this application.
The Ultimus V can be operated using the foot pedal provided, or by an external device via a DB-15 connector. Plug the foot pedal into the connector on the back of the dispenser. You can also operate the Ultimus V with an optional finger switch or a 5 to 24 VDC pulse. Connect Air Input Note: Clean, dry, filtered factory air is required to meet warranty.
Release pedal and remove tip by lifting straight up. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 15
LV Barrier Make sure that you have attached an EFD syringe barrel filled with the fluid intended for dispensing, and that the air pressure is set all the way to zero. EFD Air gap recommends the use of a Blue LV Barrier piston for watery, low viscosity materials.
For watery solvents and cyanoacrylates, request the blue EFD LV Barrier piston, available in 3cc, 10cc, and 30/55cc sizes. If you are dispensing an RTV silicone and find that the piston bounces and causes stringing, request EFD’s assistance in selecting a suitable piston.
Note: Dispenser settings and dispensing parameters can be entered manually using the keypad and buttons on the dispenser, or via Ultimus V Interactive Software. Note: To facilitate setup, begin by setting the language in which data will be displayed. Refer to “ Setting Language ”...
• Press the F2 (Save) key to save this setting. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 19
USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 20
Locking out the Set Clock item will also lock out the Set Date item. • The user can be locked out from resetting the dispensing parameters back to the starting address before the Ultimus V reaches the ending address and the final trigger value by checking the Auto Increment Reset option. •...
Page 21
Clearing a Password • Pressing and holding the Enter and 1 keys while the Ultimus V is powering up will reset the security password. • The Please Confirm Operation screen will appear. Pressing the YES function key will reset the password to ‘0000’...
Page 22
‘RESET’. Pressing the F2 function key will reset the Auto Increment Alarm. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 23
Information Screen • The information screen displays the SAP part number for the dispenser and the name Ultimus V. The Technical Support phone number and web address are also displayed. • VER: is the version number of the Main board firmware.
• Press the F3 key to Save the time setting. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 25
Press the Enter key, enter the desired vacuum, and press the Enter key again to save the setting. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Mode USING AUTO INCREMENT MODE The Ultimus V dispenser features an Auto Increment mode that can be set up to automatically adjust dispense time, pressure and vacuum settings when dispensing fluids that change viscosity over time. There are 400 unique memory locations in which different combinations of dispense time, pressure and vacuum settings can be stored.
Page 27
The total dispense cycle count for the unit is saved and will continue to increment while in Auto sequence mode. Once the trigger value is reached for the End address, the Ultimus V will automatically reset the memory cell address back to the Start address and continue increasing the memory cell address as before. The auto increment alarm will not be set in this mode.
To start over, highlight AI, then press F2 (Reset). If the AI Alarm is used, resetting the alarm will also reset the AI mode. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
End of Cycle Feedback+: This is the positive input signal for the End of Cycle Feedback solid state switch. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 30
Dispense Cycle Control with Contact Closure Initiate and an External Relay www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 31
Alarm Output+: This is the positive input signal for the Alarm Output solid state switch. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 32
24VDC Power Supply–: These pins are the 24 VDC power supply reference and return pins. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
1. RS-232 Protocol 1.1 Communication Specifications The RS-232 protocol for the Ultimus V uses the RS-232C standard. The Ultimus V acts as a terminal to the remote host PC or PLC. The Ultimus V communicates using the following settings. • Synchronous Mode: Half Duplex •...
Page 34
Connection Protocol 1.3 Communication Sequence There are two communication sequences that the Ultimus V uses. The first is a download command sequence and the other is a feedback command sequence. 1.3.1 Download Commands The Download commands are used when the Remote Host sets a parameter on the Ultimus V but does not require feedback data.
Page 35
If the host receives an ‘A0’ command, the host will send an ACK to indicate that it is ready to receive data. When the ACK from the Host is received, the Ultimus V will send a command packet that contains the data requested by the host. STX+05+D0+00001+96+ETX for example.
Page 36
The final part of the command packet is the End of Packet (0x03h) ASCII character. The following is an example of a command packet. This example uses the Pressure Set Command (‘PS’) to send a 50.0psi value to the Ultimus V. The command:...
Page 37
2. RS-232 Commands The following is a list of the RS-232 commands for the Ultimus V. Each item will give a brief description of the command, command format with a description of the data that is attached to the command, and if necessary, the format of the return command along with a description of its attached data.
Page 38
0.0000 to 9.9999. This command accepts either 3 or 4 decimal places. www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 39
This command resets the Auto Increment functions. The Ultimus V will set the Memory Address to the Start Address Value, reset the counters, and clear the auto increment alarm. If the Ultimus V is not in counter or timer mode, the dispenser will return an error (A2).
Page 40
EQ--Tttttt ttttt: Trigger Value. 00001 - 99999 2.2.21 Set the Real Time Clock Command This command sets the time on the real time clock on the Ultimus V Host Format: EB--HhhMmmAMa hh: Hours. 0-23 for 24 Hour Format, 1-12 for 12 Hour Format mm: Minutes.
Page 41
2.2.27 Dispense Command This command initiates a dispense cycle in the Ultimus V. If the unit is in timed mode, the unit will dispense for the duration currently set in dispense time parameter. If the unit is in steady mode, the unit will begin dispensing.
Page 42
Musashi FX808 protocol. 2.3.2 Memory Channel, Dispense Pressure, and Dispense Time Feedback Command This command returns the Ultimus V’s current memory channel, dispense time and dispense pressure to the host. ‘D0’ is the letter ‘D’ followed by the digit ‘0’.
Page 43
This command is the same command as the Musashi 808FX Total Status command, thus Vacuum Interval mode status is included in the command string. The Ultimus V does not support this mode; therefore this data is defaulted to safe values. ‘D0’ is the letter ‘D’ followed by the digit ‘0’.
Page 44
7-digit deposit counter. Range is 0000000 to 9999999. 2.3.10 Real Time Clock Feedback Command This command returns the time from the real time clock on the Ultimus V. ‘D0’ is the letter ‘D’ followed by the digit ‘0’. Host Format:...
Page 45
Enable Output of the Auto Increment Alarm (AO) 2.3.14 Alarm Status Feedback Command This command returns the status of each of the alarms in the Ultimus V. ‘D0’ is the letter ‘D’ followed by the digit ‘0’. Host Format:...
Cable Front RS-232 Ultimus V 7014551 Ultra 2800 Replacement Fuses 7017255 Connector Ultimus V I/O 15pos D-Sub 7014553 Backshell Ultimus V I/O 15 Pos D-Sub 7014554 Fill Valve Ultimus V 7014555 Dispense Valve Ultimus V 7014556 Proportional Valve Ultimus V...
Page 47
Replacement Parts Ultimus V Ultimus V Replacement Parts www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Page 48
Kit Detent Optimeter 7014568 Quick-Connect Adapter Piston Syringe Barrel Locking Ring www.efd-inc.com info@efd-inc.com USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006 dispensing systems are available worldwide . Sales and service of EFD ®...
Need help?
Do you have a question about the ULTIMUS V and is the answer not in the manual?
Questions and answers
what does an error P mean