Single Axis Vibration (Single); Acceleration, Transducer = 10Mv; Acceleration, Transducer = 100Mv; Velocity, Transducer = 10Mv Or 100Mv - Castle group Excieo GA2005H Operating Manual

Human & environmental vibration meter
Table of Contents

Advertisement

Single Axis Vibration (SINGLE)

Acceleration, Transducer = 10mV

Acceleration : Metric
Range 1
0.02 – 100.0 ms
Range 2
0.10 – 500.0 ms
Range 3
0.20 – 1000.0 ms
Range 4
1.00 – 5000.0 ms
* for a dB reference level of 1e
Acceleration : Imperial
Range 1
0.06 – 328.0 fts
Range 2
0.30 – 1640.0 fts
Range 3
0.60 – 3280.0 fts
Range 4
3.00 – 16400.0 fts

Acceleration, Transducer = 100mV

Acceleration : Metric
Range 1
0.002 – 10.0 ms
Range 2
0.010 – 50.0 ms
Range 3
0.020 – 100.0 ms
Range 4
0.100 – 500.0 ms
* for a dB reference level of 1e
Acceleration : Imperial
Range 1
0.006 – 33.0 fts
Range 2
0.03 – 164.0 fts
Range 3
0.06 – 328.0 fts
Range 4
0.30 – 1640.0 fts

Velocity, Transducer = 10mV or 100mV

Velocity : Metric
Low
Med Low
Med High
High
-2
Range 1
-2
Range 2
-2
Range 3
-2
Range 4
-5
subtract 20 from both the lower and upper dB levels
-2
Range 1
-2
Range 2
-2
Range 3
-2
Range 4
-2
Range 1
-2
Range 2
-2
Range 3
-2
Range 4
-5
subtract 20 from both the lower and upper dB levels
-2
Range 1
-2
Range 2
-2
Range 3
-2
Range 4
Page 103
Acceleration : dB
86.0 – 160.0 dB
100.0 – 174.0 dB
106.0 – 180.0 dB
120.0 – 194.0 dB
Acceleration : g
0.002 – 10.0g
0.01 – 50.0g
0.02 – 100.0g
0.10 – 500.0g
Acceleration : dB
66.0 – 140.0 dB
80.0 – 154.0 dB
86.0 – 160.0 dB
100.0 – 174.0 dB
Acceleration : g
0.0002 – 1.0g
0.001 – 5.0g
0.002 – 10.0g
0.010 – 50.0g
Velocity : dB
Low
Med Low
Med High
High
-6
(ref 1e
) *
-6
(ref 1e
) *

Advertisement

Table of Contents
loading

This manual is also suitable for:

Excieo ga2005sExcieo ga2005m

Table of Contents