2x.054
Minimum
Default
Type
Display Format
Coding
Value
0
millimeters
1
micro metres
P2 Linear Comms And Line Pitch Units (2x.054) defines the units used by P2 Linear Comms Pitch
(2x.052) and P2 Linear Line Pitch (2x.053) in millimeters or micrometres.
2x.055
Minimum
Default
Type
Display Format
Coding
P2 Pole Pitch (2x.055) is used to define the distance equivalent to one pole for linear position
feedback devices. If the linear position feedback device is being used with a linear motor, then P2
Pole Pitch (2x.055) should be set to the pole pitch of the motor.
2x.056
Minimum
Default
Type
Display Format
Coding
If P2 Feedback Reverse (2x.056) = 1 the position feedback is negated. This can be used to reverse
the direction of the position feedback.
2x.057
Minimum
Default
Type
Display Format
Coding
P2 Normalization Turns (2x.057) defines the number of turns bits included in the following
parameters. See P2 Normalization Turns (2x.057) for more information.
P2 Normalized Position (2x.058)
P2 Normalized Marker Position (2x.059)
F1 Normalized Freeze Position (1x.103) if P2 is the source position for freeze function F1
SI-Universal Encoder User Guide
Issue: 2
P2 Linear Comms And Line Pitch Units
0
0
8 Bit User Save
None
RW, Txt
Text
P2 Pole Pitch
0.01
10.00
32 Bit User Save
None
RW
P2 Feedback Reverse
0
0
1 Bit User Save
None
RW
P2 Normalization Turns
0
16
8 Bit User Save
None
RW
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
1000.00
Units
mm
Update Rate
Background read
Decimal Places
2
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
16
Units
Update Rate
Background read
Decimal Places
0
117