4
Mechanical Installation
Before installing or removing an option module from any drive, ensure the AC supply
has been disconnected for at least 10 minutes and refer to section 2 Safety
information on page 6. If using a DC bus supply ensure this is fully discharged before
working on any drive or option module.
WARNING
4.1
General installation
Installation of an option module is illustrated in Figure 4-1.
Figure 4-1 Installing an option module on Unidrive M600 to M702
Option module slots must be used in the following order: (Slot 3), (Slot 2) then (Slot 1).
•
Move the option module in the direction shown (1/2).
•
Align and insert the option module tab into the slot provided. This is highlighted in the detailed
view (A).
•
Press down on the option module until it clicks into place.
SI-Universal Encoder User Guide
Issue: 2
2
23