Power Supply Wiring And Grounding; Figure 16: Rsg2000 Series Phillips Screw Terminal Block; Figure 17: Rsg2000 Series Phoenix Plug Terminal Block - RuggedCom RuggedSwitch RSG2300 Installation Manual

32-port managed ethernet switch with 4 modular gigabit uplink ports
Hide thumbs Also See for RuggedSwitch RSG2300:
Table of Contents

Advertisement

2.3 Power Supply Wiring and Grounding

The RSG2300 supports dual redundant power supplies, "Power Supply 1" (PS1)
and "Power Supply 2" (PS2). The RSG2300P supports a single AC or DC power
supply, PS1, and a separate 48VDC power supply, PS2, which provides power to
the PoE ports.
The connections for PS1, PS2 and the fail-safe relay are located on the terminal
block as shown in Figure 16 and Figure 17.
RSG2300 products can be equipped with either a Phillips Screw Terminal Block
or a Phoenix Plug Terminal Block. The Phillips Screw Terminal Block has Phillips
screws with compression plates, allowing either bare wire connections or
crimped terminal lugs. We recommend the use of #6 size ring lugs to ensure
secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover which must be removed via two Phillips screws before
connecting any wires.
ensure personnel safety. Refer to Table 5 below for a description of each
terminal as well as to sections 2.3.1 through 2.3.3 for power supply wiring
examples.

Figure 16: RSG2000 Series Phillips Screw Terminal Block

Figure 17: RSG2000 Series Phoenix Plug Terminal Block

RuggedCom®
The safety cover must be reattached after wiring to
18
RuggedSwitch RSG2300 Installation Guide Rev108
Installation