Power Supply Wiring And Grounding; Figure 6: Rsg2000 Series Philips Screw Terminal Block; Figure 7: Rsg2000 Series Phoenix Plug Terminal Block - RuggedCom RuggedSwitch RSG2100P Installation Manual

Modular power over ethernet managed ethernet switch
Table of Contents

Advertisement

4.2 Power Supply Wiring and Grounding

Philips Screw Terminal with Cover
Safety Cover

Figure 6: RSG2000 Series Philips Screw Terminal Block

Phoenix Plug Terminal with Cover
Safety Cover

Figure 7: RSG2000 Series Phoenix Plug Terminal Block

The RSG2100P supports a single AC or DC power supply, "Power Supply 1 (PS1)" and a separate
48VDC power supply, "Power Supply 2 (PS2)" used to provide the power over Ethernet. The
connections for PS1, PS2 and the fail-safe relay are located on the terminal block as shown in
Figure 6 and Figure 7.
The RSG2000 Family chassis ground connection, shown in Figure 8, uses a #6-32 screw. It is
recommended to terminate the ground connection in a #6 ring lug, and to use a torque setting not
exceeding 15 in.lbs (1.7 Nm).
#6-32 screw with
ext. washer.
#6 ring lug
stainless steel standoff
Figure 8: Chassis Ground Connection
©
2008 RuggedCom Inc. All rights reserved
Philips Screw Terminal without Cover
Safety Cover
Chassis Ground
Screws
Connection
Phoenix Plug Terminal without Cover
Safety Cover
Chassis Ground
Screws
Connection
13
Terminal
Surge / Chassis
Ground Jumper
Surge / Chassis
Terminal
Ground Jumper
Rev105