2.7.2 RJ45 Twisted-Pair PoE Ports

The RSG2300P comes standard with two 10/100BaseTX IEEE 802.3af (PoE)
compliant Ethernet ports in Slot 2 (ports) and can accommodate two more, in
Slot 1. In addition to the 10/100BaseTX port features, the PoE ports provide
nominal 48 VDC at 350 mA (max 15.4W/port), auto-sensing and automatic power
off when cables are removed. Table 8 shows the RJ45 PoE pin-out assignment.
10/100BaseTx PoE Pin-out
Pin
1
2
3
6
4, 5, 7, 9

Table 8: RJ45 PoE pin-out assignment

2.7.3 Gigabit Ethernet 1000Base-TX Cabling Recommendations

The IEEE 802.3ab Gigabit Ethernet standard defines 1000 Mbit/s Ethernet
communications over distances of up to 100 meters using all 4 pairs in category
5 (or higher) balanced unshielded twisted-pair cabling. For wiring guidelines,
system designers and integrators should refer to the Telecommunications
Industry Association (TIA) TIA/EIA-568-A wiring standard that characterizes
minimum cabling performance specifications required for proper Gigabit Ethernet
operation. To ensure reliable, error-free data communication, new and pre-
existing communication paths should be verified for TIA/EIA-568-A compliance.
Table 9 summarizes the relevant cabling standards.
Cabling
Category
<5
5
5e
6
>6

Table 9: Cabling categories and 1000BaseTx compliance defined.

Follow these recommendations for copper data cabling in high electrical noise
environments:
Data cable lengths should be as short as possible, ideally limited to 3m (10ft)
in length. Copper data cables should not be used for inter-building
communications.
RuggedCom®
Description
RX + and Power -
RX - and Power -
TX + and Power +
TX - and Power +
NC
1000BaseTx
Compliant
New wire infrastructure required
No
Yes
Verify TIA/EIA-568-A compliance
No action required. New installations should be
Yes
designed with Category 5e components or higher
Yes
No action required
Connector and cabling standards to be
Yes
determined.